Title: PCM-1 to PCM-2 Upgrade Instructions Sheet 18 of 25 Rev: A Dwg: 873-4514-001
STEP 48. Select “Power Amps” and then”LPU PA’s”.
a. When first installing a PCM-2 module there is a minor font issue
associated with the TCU Panel PC that needs to be addressed. This can
cause certain text to not display properly. For example; compare the
local Panel PC “LPU PA’s” screen on your display to what is shown in
figure 29. Note that the “48V DC” title, in the upper right hand corner, is
on two separate lines. This should normally be on just one line. This font
issue only affects the Panel PC in the TCU, not computers that are used
to connect to the transmitter remotely. To correct this continue to step
49.
Figure 29
STEP 49. Lower the TCU front panel by pulling outward and down. The lowered
panel is shown in figure 6.
STEP 50. Connect a crossover ethernet cable between a computer and the top
ethernet port on the front of the PCM-2 module.
STEP 51. The front ethernet port on the PCM-2 module does not have DHCP
capability. Therefore the local area network connection on your computer must
be assigned the static IP information shown below:
a. IP Address: 192.168.2.101
b. Subnet mask: 255.255.255.000
STEP 52. Open a web browser and enter IP address http://192.168.2.100
STEP 53. Login with the username and password that was created in step 32.