Model 9100 HDRC
Handheld Dry-well
User Manual
Rev. 8A1601
Question and Answer IconNeed help?

Do you have a question about the Hart Scientific 9100 HDRC and is the answer not in the manual?

Summary

Introduction to the 9100 HDRC Dry-Well

Introduction

Overview of the Hart Scientific Model 9100 HDRC Dry-well Calibrator, its purpose, and features.

Specifications and Environmental Conditions

Specifications

Details the operating range, accuracy, stability, heating/cooling times, probe hole sizes, depth, power, size, and weight of the calibrator.

Environmental Conditions

Specifies the recommended operating temperature, humidity, pressure, voltage, vibration, and altitude conditions for safe use.

Warranty Information

Outlines the product warranty, limitations, and contact information for service or assistance.

Safety Guidelines for Operation

Safety Guidelines

Provides critical safety precautions for operating the dry-well calibrator to prevent injury and equipment damage.

Quick Start Procedures

Unpacking

Instructions for carefully unpacking the dry-well and verifying all components are present.

Set-up

Guidance on placing the calibrator, connecting the power cord, and turning it on for initial operation.

Power Connection

Details on connecting the power cord to the appropriate voltage and turning the unit on.

Parts and Controls Overview

Rear Panel Identification

Description of the rear panel components including power cord, power switch, and fan.

Prop for Inclined Position

Explanation of the prop's location, function, and usage for inclined positioning.

Front Panel Components

Details the front panel components: well block, controller display, and controller buttons.

General Operation Guide

Initial Set-up

Instructions for placing the calibrator, connecting power, and initial power-on sequence.

Setting the Temperature

Procedure for setting the desired temperature using the controller buttons and understanding temperature stabilization.

Controller Operation and Programming

Parameter Programming

Overview of controller programmability, software lock, and accessing the menu levels.

Locking and Unlocking Controller

Steps to unlock the controller parameters for modification and relock them for security.

Switching Display Units

Method to change the displayed temperature units between Celsius (°C) and Fahrenheit (°F).

Test Probe Calibration Procedures

Calibration Methods

Describes different methods for calibrating test probes, including direct and comparison calibration.

Direct Calibration Method

Procedure for calibrating a probe by directly comparing its reading to the dry-well's displayed temperature.

Comparison Calibration Method

Method for calibrating a probe against a known reference probe for improved accuracy.

Calibration of Multiple Probes

Guidance on calibrating several probes simultaneously, noting stabilization time and stem effect.

Dry-Well Thermal Characteristics

Information on understanding the thermal properties of the dry-well for optimal calibration.

Vertical Temperature Gradient

Explanation of vertical temperature gradients within the test well and how to minimize them.

Stabilization and Accuracy

Details on the time required for the dry-well to stabilize and achieve accuracy at set temperatures.

Calibration Procedure Steps

Pre-Calibration Checks

Steps to ensure all controller parameters are set correctly before proceeding with calibration.

Main Calibration Process

Accuracy specifications and the procedure for calibrating the dry-well.

Span Adjustment Procedure

Detailed steps to calculate and set the new span parameter for calibration.

Zero Adjustment Procedure

Instructions for calculating and setting the zero parameter for accurate calibration.

Accuracy Verification

Procedure for checking the accuracy of the dry-well at various set-points and repeating adjustments if needed.

Maintenance and Care

Maintenance Guidelines

Guidelines for routine maintenance, cleaning, handling, and general care of the dry-well calibrator.

Troubleshooting and Compliance

Common Troubleshooting Scenarios

Common problems encountered during operation and suggested solutions for fixing them.

CE Compliance Information

Information regarding compliance with European directives (EMC and Low Voltage) for safety and electromagnetic compatibility.

EMC Directive Details

Details on testing for electromagnetic compatibility according to the EMC Directive.

Low Voltage Directive (Safety)

Information on compliance with the Low Voltage Directive and relevant IEC safety standards.

Wiring Diagram

Schematic diagram illustrating the electrical connections and components of the 9100 Dry-Well.

Hart Scientific 9100 HDRC Specifications

General IconGeneral
Model9100 HDRC
TypeDry-Well Calibrator
Communication InterfaceRS-232
Display°C or °F
Power Supply115 VAC or 230 VAC