HARTRIDGE LIMITED IFT-c Operating and Servicing Manual
HL048 (EN) Issue 4, H1852, August 2011 7
1. Introduction
The IFT-c is designed to be used in conjunction with a Hartridge IFT-70, Testmaster 2 HH700
or a Testmaster 3 HH701 to provide an electrical signal to drive common rail injectors. When
used in conjunction with an IFT-70N it gives the ability to measure nozzle opening pressures
on traditional single stage injectors.
The IFT-c is of a steel fabricated construction with a 2 line LCD display of 20 characters. It
has a green start button, red escape button, a rotary control and 7 individual injector driver
leads.
1.1 Specification & Site Requirements
Dimensions
Height 405mm
Width 200mm
Depth 250mm
Injector type
connectivity
Delphi Solenoid
Denso Solenoid
Bosch Solenoid
Siemens Piezo
Bosch Piezo
Weight
11kg
Injection Frequency
Range
0 3000 IPM for 0-2.0 mS
(100 IPM increments)
0 2000 IPM for 2.0-3.0 mS
(100 IPM increments)
Electrical
supply
Single phase, 100 120Vac, 50 / 60 Hz
Single phase, 200 240Vac, 50 / 60 Hz
Pulse width Range
0 3.0 mS for 0-2000 IPM
(0.1mS increments)
0 2.0 mS for 2000-3000 IPM
(0.1mS increments)
Electrical
output
Single phase, 230Vac 60Hz
(Rated 1 amp)
Timer
10 120
(10 second increments)
IFT-70
Integration
16 pin automotive type connector
Shot Count
10 1000
(20, 50, 100, 200, 500 increments)
9999 (continuous running)
NOP hold time
(IFT-70n only)
0 - 1.0 sec in 0.5 sec increments, 1.0 to
5.0 in 1 sec increments.
1.2 Definition of Terms and Abbreviations
IFT-70
Injector Functional Tester
IFT-c
Injector Functional Tester - controller
NOP
Nozzle Opening Pressure (NOP)
IPM
Injections Per Minute
HH700
Hartridge Testmaster 2
HH701
Hartridge Testmaster 3
THIS IS AN UNCONTROLLED DOCUMENT downloaded by Lukas Matuska on 16 Feb 2016
Any technical intervention requires certified Hartridge training. Contact Hartridge Ltd for details.