Harvia Oy, PL 12, 40951 Muurame, Finland
14
EN 13240:2001
Harvia 10 iron stove WU100
Intended use Intermittent burning room heater
Fuel Wood
- safety distances to combustible materials
to sides
to back
500 mm
500 mm
Flue gas temperature* 240 °C
Heating output 6,7 kW
- carbon monoxide emission at 13 % O
2
p (9137 mg/m
3
)
- carbon monoxide emission (%) at 13 % O
2
p (0,7 %)
- total efficiency p (80 %)
- flue draught* 12 Pa
- refuelling loads 1,6 kg
* Stove door closed
p Pass
Table 1. Technical Data
Table 2.
Harvia 10 WU100
Sauna room volyme (m³) 20–200
Required temperature class of chimney T450
Diameter of connection opening (mm) 115
Weight (kg) ca 85
Widht (mm) 360
Depth (mm) 570
Height (mm) 750
Fire chamber Cast iron
Maximum lenght of firewood (cm) 30
Diameter of firewood (cm) 8–15