58
Release the fuel filter using a strap wrench or
a similar tool, and remove it.
59
Slightly grease the seal „1“ of the new replace-
able-cartridge filter
Assemble replaceable-cartridge filter and
tighten it by hand.
Bleed the injection system by means of the
manual fuel pump (Chapter 4.1.2).
After a short test run, check fuel filter for leak-
age; if necessary, re-tighten it by hand.
6. Operating checks and
repair work
6.1. Checking operation of air cleaner
maintenance indicator
Every 250 hours of operation, perform a routine
check on the maintenance indicator or mainte-
nance switch and the display light.
– Detach the capsule hood or side trim
(see Chapter 2).
Electric maintenance switch
60
– Turn switch key to position I.