EasyManua.ls Logo

Hatz 2M41 - Page 90

Hatz 2M41
113 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Faults 2L41C, 2M41, 2M41Z
90
HATZ
Operator’s Manual
Possible causes Remedy Chapter
Engine temperature
too high.
Check the cooling air guides
for contamination or other im-
pairments.
8.2.7 Cleaning
the cooling fan,
cooling fins and
oil cooler, page
63
Engine switches off spontaneously during operation.
Possible causes Remedy Chapter
The tank ran out of fuel
during operation.
Fill with fuel. 7.7 Refueling,
page 48
Fuel prefilter or main
fuel filter is clogged.
Change the fuel filter. 8.2.10 Changing
the fuel prefilter,
page 69
8.2.15 Change
the main fuel fil-
ter, page 79
Poly v belt torn. Renew the poly v belt. 8.2.17 Renewing
the poly v belt
and checking the
function of the
switch-off unit,
page 83
Mechanical faults. Contact Hatz service.
With automatic electrical switch-off mechanism (option)
Possible causes Remedy Chapter
Stop signal of monitoring elements for:
Oil pressure too low. Check the oil level. 7.8 Check the oil
level, page 49
Engine temperature
too high.
Check the cooling air guides
for contamination or other im-
pairments.
8.2.7 Cleaning
the cooling fan,
cooling fins and
oil cooler, page
63

Table of Contents

Other manuals for Hatz 2M41

Related product manuals