Faults 2L41C, 2M41, 2M41Z
94
HATZ
Operator’s Manual
Pos. Designation
3 Seal wire
Procedure
Step Activity
1 Check the oil level (see chapter 7.8 Check the oil level, page
49).
2 Remove the capsule hood or side trim panel (see chapter 5
Engine design, page 26)
3 Place a suitable tool, such as a screwdriver, behind the emer-
gency start lever(2) and tear the seal wire(3) between the
emergency start lever and the housing screw with a forceful
jerk.
4 Turn the emergency start lever to the start position.
5 Start the engine (see chapter 7.5 Starting the engine, page
36).
6 Eliminate the emergency situation within a few seconds.
7 Switch off the engine.
8 Immediately after the emergency operation phase:
▪ Determine and remedy the cause of the fault signal (see
chapter 9.1 Troubleshooting, page 87).
▪ If necessary, contact your nearest HATZ service station.