EasyManua.ls Logo

Haulotte HA130RTJ PRO - User Manual

Haulotte HA130RTJ PRO
156 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Maintenance book
HA32RTJ PRO - HA100RTJ PRO - HA41RTJ PRO - HA130RTJ PRO
4000392150 E02.16 USA / GB
Maintenance book
HA32RTJ PRO - HA100RTJ PRO
HA41RTJ PRO - HA130RTJ PRO
4000392120
E02.16
USA

Table of Contents

Questions and Answers

  • S
    Steven NobleAug 20, 2025
    Why platform controls do not respond on Haulotte Boom Lifts?
    • D
      diane14Aug 21, 2025
      If the platform controls of your Haulotte Boom Lift do not respond, it could be due to several reasons: * The ground control box selector key might be set to the ground control box position. Turn the ground control box selector key to platform control box position. * The 'Enable Switch' control validation device may not be enabled. Enable the device and keep it pressed down during movement. * The 'Dead man' control validation device might be activated for more than 8 seconds without movement. Release the 'Dead man' selector and reactivate it. * Not enough hydraulic oil: Top up the oil level. For other issues like a faulty joystick or solenoid valve, it is recommended to contact HAULOTTE Services®.
  • R
    Ronald BakerAug 23, 2025
    What to do if Haulotte HA130RTJ PRO Boom Lifts engine shuts down and fuel tank indicator is lit?
    • A
      Anthony BentleyAug 23, 2025
      If the engine shuts down and the fuel tank indicator is lit up on your Haulotte Boom Lift, it means the fuel tank is empty. Refill the tank to resolve this issue.
  • J
    John HunterAug 26, 2025
    Why is there low hydraulic pump pressure in my Haulotte Boom Lifts?
    • K
      Kenneth MyersAug 26, 2025
      If you experience low hydraulic pump pressure or power in your Haulotte Boom Lift, consider the following: * **Clogged air filter**: Replace the filter. * **Clogged oil filter**: Replace the oil filter cartridge. * **Clogged fuel filter**: Replace the filter. * **Faulty accelerator coil**: Replace the coil. * **Faulty accelerator fuse or relay**: Replace the accelerator relay or fuse. For issues like engine speed being too low or leak/air in the fuel circuit, it is recommended to contact HAULOTTE Services®.
  • R
    Renee Wilson DDSAug 27, 2025
    What causes the overload indicator and buzzer to activate with unresponsive platform controls in Haulotte HA130RTJ PRO?
    • B
      bakerkimberlyAug 28, 2025
      If the platform controls of your Haulotte Boom Lift do not respond, the buzzer is on, and the overload indicator is on, it could be due to: * **Platform overload**: Remove some weight to not exceed the authorized limit. * **Platform touching the ground**: Lift the jib from the ground control box. * **Jib cylinder at the lower or upper mechanical stop position**: Control the jib from the ground control box. * **Jib in transport position**: Control the jib from the ground control box. For a faulty weighing system, it is recommended to contact HAULOTTE Services®.
  • T
    Tara CaseyAug 30, 2025
    What does it mean when the radius limit indicator is on and platform controls do not respond in Haulotte HA130RTJ PRO?
    • M
      Mrs. Sherry StewartAug 30, 2025
      If the platform controls of your Haulotte Boom Lift do not respond and the radius limit indicator is on when a movement control is activated, it means the movement is not permitted. Bring the machine back within the authorized zone by retracting the telescope, lowering the boom, or lifting the arm to enable movement.
  • S
    Steven ReedSep 1, 2025
    What to do when the tilt indicator is on, buzzer sounds, and platform controls are unresponsive on Haulotte Boom Lifts?
    • J
      james73Sep 1, 2025
      If the platform controls of your Haulotte Boom Lift do not respond and the buzzer is sounding because the tilt indicator is on, it means the tilt or slope exceeds the authorized limit. Stow the machine and move to flat ground.
  • S
    Steven HarveySep 4, 2025
    What does it mean when Haulotte Boom Lifts engine stops during boom movement and the defect indicator flashes twice?
    • M
      Megan LoganSep 4, 2025
      If the engine stops during boom movement, will not restart, and the defect indicator flashes in sequences of 2 flashes on your Haulotte Boom Lift, it may be due to faulty platform control box joystick(s). It is recommended to contact HAULOTTE Services® to replace the joystick(s).
  • H
    hartkevinSep 6, 2025
    Why won't the axles retract/extend and the buzzer is sounding on my Haulotte Boom Lifts?
    • K
      Katie JonesSep 6, 2025
      If the axles of your Haulotte Boom Lift do not retract/extend and the buzzer is sounding, it means the machine is not in the required configuration. Turn the ground control box selector key to the ground control box position, stow the machine completely, and align the turret with the machine.
  • I
    idavisSep 8, 2025
    What causes a discontinuous buzzer and no driving in Haulotte HA130RTJ PRO Boom Lifts?
    • W
      whitneymeghanSep 8, 2025
      If your Haulotte Boom Lift is not driving and a discontinuous buzzer is sounding, it indicates that the platform is at the working limit. Retract the boom telescope to resolve this issue.
  • K
    Kevin BryantSep 12, 2025
    What does it mean when the overload indicator is on, buzzer sounds, defect indicator flashes 9 times, and platform controls are unresponsive on Haulotte Boom Lifts?
    • B
      Bryan GrahamSep 12, 2025
      If the platform controls of your Haulotte Boom Lift do not respond, the buzzer is on, the overload indicator is on, and the defect indicator flashes in sequences of 9 flashes, it indicates a faulty platform overload circuit. Reinitialize the system. If the problem persists, it is recommended to contact HAULOTTE Services® to check the electrical weighing circuit.

Summary

Safety Precautions

Recommendations

General advice and guidelines for safe operation and maintenance.

Maintenance

Maintenance Schedule

Schedule outlining required maintenance tasks based on time or hours.

Inspection Program

Overview of different inspection types and their frequency.

Daily Inspection

Procedures and checklists for daily pre-operation checks.

Periodic Inspection

Detailed inspection procedures performed at regular intervals.

Reinforced Inspection

Thorough inspection of machine structure at specific intervals or conditions.

Major Inspection

Comprehensive inspection for suitability, integrity, and function after extended use.

Diagnosis Assistance

Troubleshooting

Table of common problems, probable causes, and solutions.

Electric Circuit

Hydraulic Circuit

Haulotte HA130RTJ PRO Specifications

General IconGeneral
BrandHaulotte
ModelHA130RTJ PRO
CategoryBoom Lifts
LanguageEnglish

Related product manuals