EasyManua.ls Logo

Hausmann XPERT PNT138-R - User Manual

Hausmann XPERT PNT138-R
24 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Modèle / Model:
PNT138-R
PNT138-R
68125013
Operators Manual (p.15)
Manuel de l'utilisateur (p.2)
2-IN-1 PNEUMATIC NAILER
CLOUEUSE PNEUMATIQUE 2 EN 1
2-IN-1 PNEUMATIC NAILER
CLOUEUSE PNEUMATIQUE 2 EN 1
CONSERVEZ CE GUIDE
Vous aurez besoin de ce guide pour les règles de sécurité, les procédures d'utilisation et la garantie.
Conservez-le avec votre facture d'origine dans un endroit sûr et au sec pour référence future.
SAVE THIS MANUAL
You will need this manual for safety instructions, operating procedures, and warranty.
Put it and the original sales invoice in a safe, dry place for future reference.
QUESTIONS? 1-866-206-0888
Notre personnel du service à la clientèle est disponible pour vous aider.
Pour obtenir de l'aide pour le montage de votre produit, pour signaler
des pièces endommagées ou manquantes, ou pour toute autre
information, veuillez composer notre numéro sans frais: 1-866-206-0888.
Enregistrez votre produit
Nous vous invitons à enregistrer votre produit en ligne afin de faciliter les
communications; pour ce faire, veuillez visiter le
www.outilshaussmann.com
Our Customer service staff is available to help you.
For help with product assembly, to report damaged or missing parts, or
for any other information, please call our toll-free number:
1-866-206-0888.
Register your product
We invite you to register your product online to make future
communications easier. To do so, simply visit our website
www.haussmanntools.com.

Questions and Answers

  • J
    Jason SilvaAug 12, 2025
    What to do if Hausmann XPERT PNT138-R Tools fasteners jam in the tool or magazine?
    • U
      uburkeAug 13, 2025
      If fasteners jam in your Hausmann Tools, several factors could be responsible. It could be that the joint guide is worn, in that case you should replace the joint guide. Ensure that you are using only the recommended and undamaged fasteners, as using the wrong size or damaged fasteners can cause jamming. Check if the magazine or front plate screws are loose and tighten them. A damaged blade in the piston assembly can also cause this issue, so consider replacing the piston assembly.
  • A
    alexanderwrightAug 16, 2025
    How to fix air leak at the trigger area of Hausmann XPERT PNT138-R Tools?
    • J
      Jasmine HerreraAug 16, 2025
      To fix an air leak at the trigger area of your Hausmann Tools, there are several potential causes to investigate. Start by checking the O-ring in the trigger valve for damage or cracks and replace it if necessary. Inspect the trigger valve head for damage and replace it if needed. Also, examine the trigger valve stem, seal, and O-ring for any signs of damage, replacing any affected components.
  • B
    bryanericAug 20, 2025
    Why Hausmann XPERT PNT138-R will not drive fasteners down tight?
    • D
      Daniel LewisAug 20, 2025
      If your Hausmann Tools won't drive fasteners down tight, it could be due to a worn blade in the piston assembly, which requires piston assembly replacement. Insufficient power can also be a factor, so adjust the regulator to ensure adequate air pressure. Slow cycling and loss of power can occur if the cylinder cap spring has broken coils or reduced length, or if the exhaust port of the cylinder cap is restricted; in this case check the cylinder cap spring for broken coils or reduced length or if exhaust port of cylinder cap is restricted.
  • J
    Justin YoungAug 23, 2025
    What to do if Hausmann XPERT PNT138-R skips fasteners?
    • L
      Lisa KeyAug 25, 2025
      If your Hausmann Tools is skipping fasteners, it might be due to several reasons. A worn bumper or damaged spring could be the cause, so replace the bumper or pusher spring. Dirt in the front plate can also interfere, so clean the drive channel of the front plate. Check for a worn or dry O-ring on the piston and replace or lubricate it. Also, a damaged O-ring on the trigger valve can cause this issue, so replace the O-ring. Finally, a leaking cylinder cap can also lead to skipped fasteners, so replace the seal.
  • F
    fshawAug 27, 2025
    Why Hausmann XPERT PNT138-R driving fasteners too deeply?
    • S
      Stephanie MossAug 28, 2025
      If your Hausmann Tools is driving fasteners too deeply, it could be due to a worn bumper, which means you should replace it. Alternatively, the air pressure might be too high, so adjust the air pressure at the regulator.
  • C
    Christina HarveyAug 31, 2025
    Why Hausmann XPERT PNT138-R runs slowly or has power loss?
    • K
      Kara FloresAug 31, 2025
      If your Hausmann Tools runs slowly or experiences power loss, add oil as instructed and check the air supply. Also, a broken spring in the cylinder cap could be blocking it, so replace the spring. Alternatively, the exhaust port in the cylinder cap might be blocked, so replace any damaged internal parts.
  • B
    bairdkathleenSep 4, 2025
    How to fix air leak between body and cylinder cap of Hausmann Tools?
    • A
      Ashley CooperSep 4, 2025
      If there's an air leak between the body and cylinder cap of your Hausmann Tools, first check if any screws are loose and tighten them. If the screws are not the problem, inspect the seal for damage and replace it if necessary.
  • H
    Heather ChapmanSep 8, 2025
    How to fix air leak between body and front plate of Hausmann XPERT PNT138-R?
    • J
      jonathan27Sep 8, 2025
      To address an air leak between the body and front plate of your Hausmann Tools, examine the piston O-ring and bumper for any signs of damage. If either the O-ring or bumper is damaged, replace it.