EasyManua.ls Logo

Haussmann Xpert DP1200 - User Manual

Default Icon
28 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Manuel de l’utilisateur (p.1)
Operator‘s manual (p.15)
PERCEUSE À COLONNE À VITESSE
VARIABLE 12 PO
AVEC LASER
12” VARIABLE SPEED
DRILL PRESS
WITH LASER
Modèle no. / Model no.
58485003 / DP1200
QUESTIONS?
1-866-206-0888
Notre personnel du Service à la Clientèle est disponible pour vous
aider. Dans le cas d’une pièce endommagée ou manquante, la plu-
part des pièces de remplacement seront expédiées de notre usine.
Pour de l’aide immédiate avec le montage, ou pour en savoir plus
sur le produit, composez notre numéro sans frais : 1-866-206-0888.
Our Customer Service staff are ready to provide assistance. In the
case of a damaged or missing part, most replacement parts ship
from our facilty. For immediate help with assembly, or for additional
product information, call our toll-free number: 1-866-206-0888
CONSERVEZ CE GUIDE
Vous en aurez besoin pour les règles de sécurité, le fonctionnement et
la garantie. Conservez-le dans un endroit sûr, au sec.
SAVE THIS MANUAL
You will need this manual for safety instructions, operating procedures,
and warranty. Put it and the original sales invoice in a safe, dry place
for future reference.

Questions and Answers

  • N
    Nathan MontoyaAug 14, 2025
    Why won't my Haussmann Xpert DP1200 motor start?
    • P
      pthompsonAug 14, 2025
      The motor may not start due to several reasons: * Low voltage: Check the power supply. * Short circuit in the line cord or plug: Inspect for faulty insulation or shorted connections. * Short or open circuit in the motor: Check the motor connections. * Incorrect fuses or circuit breakers: Replace them with the correct ones. * Defective switch or capacitor: Replace the switch or capacitor.
  • J
    Jonathan EvansAug 18, 2025
    What to do if my Haussmann Xpert DP1200 Power Tool motor stalls or doesn't reach full speed?
    • J
      Jeffrey TapiaAug 18, 2025
      If the motor stalls or fails to reach full speed, it could be due to: * Power overload: Reduce the workload on the power supply. * Low voltage: Check the power supply. * Undersized line cord: Use a line cord of adequate size or reduce the wiring length. * Motor overload: Reduce the load on the motor. * Short circuit or loose connection in the motor: Inspect the motor connections. * Incorrect fuses or circuit breakers: Replace them with the correct ones.
  • C
    Cynthia FletcherAug 21, 2025
    Why does my Haussmann Xpert DP1200 motor overheat?
    • R
      rolsenAug 21, 2025
      The motor may overheat because it is overloaded. Reduce the load on the motor and turn off the machine until the motor cools down.
  • E
    egilbertAug 25, 2025
    How to fix a noisy Haussmann Xpert Power Tool?
    • C
      Cory JordanAug 25, 2025
      Noisy operation can be caused by: 1. A loose spindle pulley: Verify the tightness of the retaining nut on the pulley and adjust if necessary. 2. A loose motor pulley: Tighten the set screw in the motor pulley. 3. Incorrect belt tension: Adjust the tension.
  • J
    Jose WilliamsAug 27, 2025
    How to reduce excessive drill bit runout in my Haussmann Xpert Power Tool?
    • M
      mwilliamsAug 27, 2025
      Excessive drill bit runout can be caused by: * Improper chuck installation: Install the chuck properly. * Improper drill bit installation: Install the drill bit correctly in the chuck. * Bent drill bit: Replace the drill bit. * Worn bearings: Replace the bearings.
  • M
    Margaret LambertAug 31, 2025
    Why is my Haussmann Xpert Power Tool drill bit burning?
    • D
      Dorothy BowersAug 31, 2025
      A drill bit can burn due to: * A dull drill bit: Replace the drill bit. * Incorrect speed: Choose the proper speed. * Chips in the hole: Clean the chips.
  • M
    Misty PrestonSep 3, 2025
    Why does my Haussmann Xpert DP1200 slow down during operation?
    • J
      Jennifer FranklinSep 3, 2025
      The machine may slow down if you are applying too much pressure during operation. Ease up on the pressure.
  • C
    Christine WestSep 6, 2025
    What to do if the chuck doesn't stay attached to the spindle of my Haussmann Xpert DP1200?
    • B
      Bethany ConwaySep 6, 2025
      If the chuck does not stay attached to the spindle, it may be due to oil, grease, or dirt on the tapered surfaces of the chuck or spindle. Clean the surfaces.
  • G
    Gary VaughnSep 10, 2025
    How to adjust quill return speed on my Haussmann Xpert DP1200 Power Tool?
    • K
      kennethscottSep 10, 2025
      If the quill return is too fast or too slow, it is likely due to improper spring tension. Adjust the spring tension accordingly.

Haussmann Xpert DP1200 Specifications

General IconGeneral
Power1200 W
Drill capacity (steel)13 mm
Chuck size13 mm
Voltage230 V
Frequency50 Hz