T
Tracy WhiteAug 17, 2025
What to do if my Hayward H250FDN Heater shows 'Ignition Failure'?
- KKyle WillisAug 17, 2025
If your Hayward Heater is experiencing ignition failure, you should inspect the ignition system for faults.
What to do if my Hayward H250FDN Heater shows 'Ignition Failure'?
If your Hayward Heater is experiencing ignition failure, you should inspect the ignition system for faults.
What to do if my Hayward H250FDN displays a 'Communication Error Between Control Module and Display Interface Assembly'?
If your Hayward Heater shows a communication error between the control module and the display interface assembly, verify the connections between these components.
What to do if my Hayward Heater displays 'Temperature Sensor (thermistor) input failure'?
If your Hayward Heater shows a 'Temperature Sensor (thermistor) input failure', check the temperature sensor and replace it if necessary.
What to do if my Hayward H250FDN Heater shows 'Ignitor Circuit Open'?
If your Hayward Heater displays 'Ignitor Circuit Open', check the ignitor circuit for continuity.
What to do if my Hayward H250FDN indicates 'Keypad failure'?
If your Hayward Heater indicates a 'Keypad failure', the solution is to replace the keypad.
What to do if my Hayward Heater displays 'Maximum return water temperature exceeded and / or rapid water temperature rise'?
If your Hayward Heater displays 'Maximum return water temperature exceeded and / or rapid water temperature rise', check the water temperature sensors and system settings.
What to do if my Hayward Heater shows 'Flame present with Gas Valve not energized'?
If your Hayward Heater shows 'Flame present with Gas Valve not energized', check the gas valve and ignition system.
What to do if my Hayward H250FDN displays 'Voltage polarity reversed, low voltage detected'?
If your Hayward Heater displays 'Voltage polarity reversed, low voltage detected', correct the polarity and ensure proper voltage is supplied.
What to do if my Hayward H250FDN Heater shows 'Water Pressure Switch, Vent Pressure Switch, or Temperature Limit Switch Fault'?
If your Hayward Heater indicates 'Water Pressure Switch, Vent Pressure Switch, or Temperature Limit Switch Fault', inspect all associated switches for proper operation.
What to do if my Hayward H250FDN displays 'Blower Vacuum Switch open'?
If your Hayward Heater displays 'Blower Vacuum Switch open', inspect the blower vacuum switch for faults.
Type | Natural Gas |
---|---|
BTU Input | 250, 000 BTU |
Application | Pool and Spa |
Ignition | Electronic |
Heat Exchanger | Cupro Nickel |
Control Panel | Digital LED |
Thermal Efficiency | 84% |
Minimum Flow Rate | 20 GPM |
Maximum Flow Rate | 120 GPM |
Warranty | 1 Year Limited |