With power off, measure resistance, comparing
each terminal to ground. IF any terminal shows
continuity, replace the gas valve (pg. 25). IF OK, go
to step 3F.
ICB wiring
Inspect ICB wiring. IF wiring is damaged, replace
the wire harness with a new wire harness kit (pg.
25). IF OK and the problem still exists, replace the
ICB (pg. 25)
Verify gas valve is not shorted
36
3. Open F1 Fuse (cont.)
When testing the gas valve, if continuity appears between any wires and ground, then
this implies a short has occurred and the gas valve will need to be replaced.
Step 3E
Step 3F