Summit/EnergyTherm/HeatMaster/EasyTemp Setup Menu
PRESS AND HOLD
SET BUTTON
5 SECONDS
Loc
Release SET button and press up arrow until 50 appears
This will unlock settings menu. Press SET again
AFF
P_S-POOL_SPA
Sets heat pump to operate only in
pool or spa mode , or in both modes
PHL
61-95 F
Set high pool limit
using up or down arrows
SHL
Set high spa limit
using up or down arrows
61-104 F
CAL
Calibrate water temperature sensor
+ 5 F
CAD
Calibrate coil temperature sensor
+ 5 F
P_S
N
DB1
Calibrate temperature differential
(dead band between on and off)
0.2-2 F
Press down arrow for
normal operation
OR
E
Press up arrow for
external controller
Not used
Combination Key Functions
Set + Dn
Bypass 3 minute time delay
Set + Up
Display coil temperature
Set+Up+Dn
Reset factory defaults