EasyManua.ls Logo

Hayward WG1030AV User Manual

Hayward WG1030AV
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
ISDUALSWG8 Rev A
1
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
DUAL SUBMERGED
SUCTION OUTLET SET
and
REPLACEMENT COVERS
[Commonly called main drains]
Owner’s Manual
For Models: WG1030, WG1048, WG1049, WG1051, WG1052, WG 1053, WG1054, WG1153, WG1154
Covers: WGX1048E, WGX1048EDGR, WGX1048EGR, WGX1048EBLK which are suitable for these models
This is the safety-alert symbol. When you see this symbol on your equipment or in this manual, look
for one of the following signal words and be alert to the potential for personal injury.
WARNING warns about hazards that could cause serious personal injury, death or major property
damage and if ignored presents a potential hazard.
CAUTION warns about hazards that will or can cause minor or moderate personal injury and/or
property damage and if ignored presents a potential hazard. It can also make consumers aware of
actions that are un
p
redictable and unsafe.
Hayward Industries Inc.
400 Connell Drive Suite 6100
Berkeley Heights, NJ 07922
Phone: (908) 355.7995
www.hayward-pool.com
Contents
Product Warnings .…………..…..…2
Recommended System ……..……..4
Installation……….…………..….….….5
Operation ………………………….…...6
Replacement Parts…………..………6
Warranty & Registration …..…..…8
When installing and using this equipment basic safety precautions
shall always be followed including the following:
IMPORTANT SAFETY INSTRUCTIONS
READ, FOLLOW AND UNDERSTAND ALL WARNINGS AND INSTRUCTION
S
Question and Answer IconNeed help?

Do you have a question about the Hayward WG1030AV and is the answer not in the manual?

Hayward WG1030AV Specifications

General IconGeneral
BrandHayward
ModelWG1030AV
CategoryPlumbing Product
LanguageEnglish

Summary

Safety Alert Symbol and Signal Words

Safety Alert Symbol and Signal Words

Explains the safety-alert symbol and signal words (WARNING, CAUTION) for potential hazards.

Suction Entrapment Hazard

Reducing Entrapment Hazards

Lists precautions for suction outlets to prevent entrapment, including spacing and flow rates.

Pressure Test Plug Warning

Warns about the risk of entrapment from unremoved pressure test or winterization plugs.

Debris Warning

Warns about increased entrapment risk from blocked suction outlet components.

Suction Outlet Component Lifespan

Discusses finite life of suction outlet components and the need for frequent inspection and replacement.

Equipment Positioning Caution

Advises positioning pool equipment to prevent children from accessing the pool.

Hazardous Pressure Warning

Warns about hazardous pressure during circulation system operation and servicing.

Separation Hazard Warning

Warns about violent separation of pump/filter components due to improper assembly or operation.

Electrical Safety Warnings

Electrician Notes on Bonding

Provides specific instructions for electricians regarding grounding and bonding requirements.

Pool Type Caution

Advises that Hayward pumps are for permanently-installed pools, not storable ones.

Hyperthermia Risk Warning

Details safety rules for hot tubs to avoid hyperthermia, including temperature limits and precautions.

Hyperthermia Effects

Lists symptoms and effects of hyperthermia, such as unawareness and physical inability to exit.

Recommended System Flow Rate

System Specifications and SOFA Ratings

Details specifications for suction outlet fitting assemblies (SOFA) and their blockable ratings.

System Diagram 1 Example

Illustrates a dual suction outlet system configuration with two outlets on the floor.

System Diagram 2 Example

Illustrates a dual suction outlet system with outlets on floor and wall.

Installation Instructions

Field-Fabricated Sump Requirements

Outlines requirements for field-fabricated sumps for specific models, referencing diagrams.

Component Preparation and Fastener Use

Covers cleaning components, using specific fasteners, and torque recommendations for installation.

Modification Restrictions

States that no field modifications are allowed to SOFA structure or flow path without recertifying.

Winterization Procedures

Provides instructions for winterizing suction outlet fittings, including cover removal and plug installation.

Fastener and Threaded Insert Repair

Details procedures for inspecting, repairing, or replacing fasteners and threaded inserts for covers.

SOFA Component Lifespan and Replacement

Explains the finite life of SOFA components and the need for regular inspection and replacement.

Operation and Spare Parts

Daily Operation Checks

Outlines daily checks for covers and fasteners for damage or tampering during operation.

Spare Parts List for WG1048/WG1049 Series

Lists available spare parts for WG1048/WG1049 series, including covers, rings, gaskets, and plugs.

Spare Parts List for WG1051/WG1052/WG1053/WG1054 Series

Lists spare parts for WG1051/WG1052/WG1053/WG1054 series, including covers, plugs, and notes.

Spare Parts and Installation Notes

Spare Parts List for WG1153/WG1154 Series

Lists spare parts for WG1153/WG1154 series, including collars, covers, and plugs.

Spare Parts List for WG1030 Series

Lists spare parts for WG1030 series, including covers and screws.

Notice for Field Fabricated Outlets

Refers to Page 5 for information regarding field fabricated outlets.

Limited Warranty and Product Registration

Hayward Limited Warranty Terms

Details the one-year limited warranty for Hayward products, covering defects in materials and workmanship.

Product Registration Information

Instructions for product registration, including filling out the warranty card and online registration.

Related product manuals