The Health o meter® Professional ProPlus® Display Module is a sophisticated microprocessor-technology electronic scale designed for accurate, reliable, and repeatable weight measurements, making the weighing process simple, fast, and convenient. It can be operated using an included AC adapter or by six D-cell batteries (not included).
Function Description
The ProPlus® Display Module serves as the primary interface for Health o meter® Professional scales, allowing users to perform various weighing operations, manage patient data, and configure scale settings.
- Weighing: The core function involves measuring the weight of an object or patient. The scale uses motion-sensing technology to determine the actual weight of a moving patient, with an option to switch to "Live Weight" mode where the display fluctuates with patient movement.
- Zeroing: The "ZERO" button allows the user to zero the scale prior to weighing, ensuring accurate measurements.
- Hold/Release: The "HOLD/RELEASE" button holds the displayed weight value until pressed again to clear it. It also functions as a scroll-down button within the menu.
- Reweigh: This feature enables repeated weighing of a patient without requiring them to step off the scale, useful for monitoring weight changes.
- Units Toggle: The "KG/LB" button toggles the display between kilograms and pounds. It also serves as a scroll-up button in the menu.
- Tare Function: The tare function subtracts the weight of an object (e.g., a wheelchair or shoes) from the total weight, providing the patient's net weight. Tare can be set automatically (Push Button Tare) by pressing the "TARE" button while an object is on the platform, or manually (Keypad Tare) by entering a specific tare value using the keypad. The tare value is stored in memory until changed, cleared, or the scale is turned off.
- Tare Weight Limits: The maximum tare weight varies by scale model: 250lb (2101KL, 2500KL, 2600KL, 2650KL & 2700KL), 200lb (2400KL), 150lb (1100KL & 1600KL), and 125lb (2000KL).
- BMI Calculation: The "BMI" button prompts the user to enter the patient's height to calculate their Body Mass Index. Height is entered in 1/4" increments for pounds (1/4", 1/2", 3/4") or 1cm increments for kilograms. BMI is not calculated for patients 24 pounds (12 kg) or less.
- Patient ID Entry: The "ID" button allows entry of a patient's identification number, which is stored with all subsequent weighings until cleared or a new ID is entered.
- Menu Navigation: The "MENU" button provides access to scale settings and data management options. Navigation is done using the up/down keys or by entering the associated menu position number. The menu is initially locked and requires pressing and holding the "MENU" key for 5 seconds to temporarily reactivate it.
- Data Management: The scale manages patient data including ID, weight, height, tare, and BMI. Data can be transferred to a PC ("Auto Download") or stored in memory ("Store In memory"). The maximum capacity for stored files is 270. "Auto Download" is the default, transferring data to a PC when the patient steps off the scale or the HOLD/RELEASE button is pressed. If no PC is connected, data is lost unless stored in memory. If memory is full, the user is prompted to transfer or clear data.
- PC Communication: The display uses an escape protocol for communicating with a PC via USB and serial ports, enabling commands and data transfer.
Important Technical Specifications
- Capacity and Resolution:
- 2700KL, 2650KL, 2600KL, 2500KL, & 2101KL: 1,000 lb x 0.2 lb / 1/4 lb / 4 oz (454 kg x 0.1 kg)
- 2400KL: 800 lb x 0.2 lb / 1/4 lb / 4 oz (360 kg x 0.1 kg)
- 1100KL & 1600KL: 700 lb x 0.2 lb / 1/4 lb / 4oz (310 kg x 0.1 kg)
- 2000KL: 400 lb x 0.2 lb / 1/4 lb / 4 oz (181 kg x 0.1 kg)
- Power Requirements:
- USA-CSA models: Adapter model ADPT 31* (120 VAC -9V DC 60Hz, included) or 6 D cell batteries (not included).
- Other models: Adapter model ADPT 30* (120-240 VAC- 9V DC 50-60 Hz, not included).
- Only Health o meter® Professional provided power supplies should be used.
- Environmental Conditions:
- Operating Temperatures: 50°F to 95°F (10°C to 35°C)
- Storage Temperatures: 30°F to 125°F (0°C to 50°C)
- Humidity: 85%
- PC Communication Protocol (Serial/USB):
- Baud rate: 9600
- Parity: None
- Databits: 8 bits
- Stopbits: 1 bit
- Startbits: 1 bit
- Hardware handshake: None
Usage Features
- Display Modes: Weight can be displayed in fractional pounds (1/4, 1/2, 3/4 lb), pounds and ounces (4 oz resolution), or decimals (0.2 lb resolution). These settings do not affect kilogram measurements.
- Auto Hold Time: Configurable duration (up to 20 seconds) for displaying the weight reading after it's determined, regardless of whether the patient remains on the platform. Default is no Auto Hold Time.
- Sleep Time: Configurable time (up to 10 minutes, default 1 minute) before the scale enters "STANDBY" mode due to inactivity.
- Auto Off Time: Configurable time (up to 60 minutes, default 10 minutes) before the scale automatically turns off due to inactivity. Can be disabled by setting to zero.
- Tone Volume: Adjustable volume for keypad tones, stable weight tones, and alarm tones.
- Display Date and Time: Option to turn on/off the display of date and time.
- Display Backlight: Adjustable brightness for the display backlight.
- Display Contrast: Adjustable contrast for the LCD.
- Live Weight Mode: Option to deactivate motion-sensing and activate Live Weight mode, where the weight fluctuates with patient movement. The REWEIGH button can be used to verify a weight in this mode.
- System Settings:
- Set Time & Date: Allows setting the current time (AM/PM or 24-hour format) and date using the keypad.
- About: Displays the software version of the display.
- Display 24 Hour: Toggles between 12-hour (AM/PM) and 24-hour time formats.
- User Settings:
- Retain Entered Values: Allows the user to retain the same ID, height, and TARE values between weighings. If disabled, these values must be re-entered for each reading.
- Display Height & ID: Displays the patient's height and ID at the bottom of the screen, recommended for verification.
- Prompt For Height: If activated, the user is prompted to enter the patient's height after every weighing (30-second entry window).
- Prompt For ID: If activated, the user is prompted to enter the patient's ID after every weighing (30-second entry window).
Maintenance Features
- General Maintenance: Before first use and after periods of non-use, check the display for proper operation, damage, wear, and tear. Inspect the AC adapter for cord damage or bent prongs. Refer to the parts list for replacement parts if needed.
- Cleaning:
- Disconnect the scale from the AC power source before cleaning.
- Clean all external surfaces with a clean damp cloth or tissue, using anti-bacterial soap and water if necessary. Dry with a clean soft cloth.
- Do not immerse the display in any liquid solution.
- Do not use Isopropyl Alcohol or other cleaning solutions.
- Do not use abrasive cleaners.
- Battery Installation/Replacement:
- Unplug the display from all power sources.
- Remove the battery cover using a Phillips screwdriver.
- Disconnect the battery holder cable connector.
- Carefully remove the battery holder.
- Replace batteries with new ones (EVEREADY Energizer® e2™ batteries are recommended).
- Carefully reposition the battery holder and reconnect the cable.
- Attach the battery cover and install the screw.
- Caution: If the "LOW BAT" indicator activates, replace batteries or connect to AC power for accurate weighing. Remove batteries if the scale will not be used for a prolonged period.
- System Test:
- Battery Test: Displays the estimated remaining battery life. Requires the display to be powered by batteries only (unplug from AC power source).
- USB Connection Test: Tests the connection to a PC, displaying "Connection is OK" or "NO Connection." If "NO Connection" is shown, check USB connections and retest.
- Diagnostic Test (UI Test): A routine to test the User Interface hardware (LCD, keypad). The user must press keys as prompted on the screen. An "UI Error Failure" message indicates a problem requiring service.
- Calibration Procedure: All Health o meter® Professional scales are factory calibrated and do not require calibration prior to use. Calibration can be performed in kg or lb. The procedure involves:
- Turning off the display, then pressing and holding "HOLD/RELEASE" while pressing "ON/OFF."
- Setting the calibration weight (at least 1/2 of scale capacity) using the keypad.
- Ensuring the scale is clear, then pressing "ENTER."
- Waiting for Zero Calibration to complete.
- Loading the scale with the required weight and pressing "ENTER."
- Waiting for Weight Calibration to complete.
- Checking for "Factor OK" or "Factor Fail" message.
- The display will reboot and return to normal operation.