Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05
12
Figure 3. Framing Dimensions for SL D-Series and DVP-Series Pipe
A B C D* E*
37 33 16 1/4” 36 1/2” 24 3/8
Framing should be constructed of
2 X 4 lumber or heavier. The
framing headers may rest on the
fireplace stand-offs.
WARNING:
To ensure proper clearances
the front framing header must be
installed on its narrow edge and
to the front of the frame.
A
B
C
Step 2. Framing the Fireplace for DVP-Series
and SL D-Series Pipe
Fireplace framing can be built before or after the fireplace is
set in place. Framing should be positioned to accommo-
date wall coverings and fireplace facing material. The dia-
gram below shows framing reference dimensions.
CAUTION: MEASURE FIREPLACE DIMENSIONS AND
VERIFY FRAMING METHODS AND WALL COVERING
DETAILS BEFORE FRAMING.
*The center of the framing hole is one inch (25.4mm)
above the center of the horizontal vent pipe.
VENT
FRAMING
HOLE
E
D