3
Hearth & Home Technologies • IFT-RC400U User Manual • 2564-983 • 10/20
HOT
This indicates that the appliance is still hot for 20 minutes
after teh appliance is turned o󰀨.
Remote Control
Battery
Remote control battery life indicator. If the batteries on
your remote are low, a notication will display on the
screen asking you to ‘Replace Remote Batteries’ or ‘Must
Replace Remote Batteries to Operate Appliance’.
Refer to Replace Remote Batteries Section.
Note: To extend the time between replacing batteries,
Lithium Ion and rechargeable NiMH AAA batteries can be
used.
INDICATORSINDICATORS
Cold Climate
This function turns on a small pilot ame and keeps the
air inside your appliance warm while not in use. It is a
useful feature in colder weather to minimize condensa-
tion on the appliance glass.
Note: This feature is disabled when a Power Vent is
installed on the appliance.
Note: The continuous pilot will automatically turn OFF
after 166 hours if appliance is not actively used. If Flame
ON is activated before 166 hours, the automatic timer will
re-start.
Temperature Display
You can toggle the temperature display between °F and
°C by tapping on the Room Temperature display.
* = Optional Feature
Power Vent*
Power Vent technology makes it possible to install a gas
appliance virtually anywhere. The Power Vent is a fan
powered accessory that pulls exhaust from the appliance
providing longer and more exible venting congurations.
A Power Vent is a standard accessory on some products
and an option on others. When a Power Vent is detected,
a pre-purge of 120 seconds is automatically required.
During this time, the power icon is temporarily replaced
with 2min, 90s, 60s, and 30s, denoting the countdown
until the appliance turns on. All other functions, except
for TURN FLAME OFF are disabled during this time.
The Power Vent is always ON when the ame is ON.
When the ame is turned o󰀨, a post-purge time of
approximately 20 minutes will occur.
Cold-climate function and battery backup are disabled if
a Power Vent is used.
Fan Speed*
If your appliance is equipped with the fan feature, use
this function to increase or decrease the amount of heat
released into your room. A built-in delay timer will turn
the fan on three minutes after your appliance has been
running to prevent cool air from being pushed into the
room. If the ame is turned o󰀨 with the fan ON, the fan
will continue to run for 12 minutes then shutdown as long
as the ame stays o󰀨.
Your appliance will remember the previous fan speed
setting and automatically adjust to that level 3 minutes
after start-up.
Diagnostics Menu
Tap anywhere in the gray indicator bar area to display all
functions below. When red, it indicates an error has been
detected.
FUNCTIONSFUNCTIONS
IFT Wi-Fi Module (IFT-WFM) Reset
If the IFT-ECM is equipped with the IFT-WFM, the IFT-
RC400 can be used to reset the IFT-WFM to factory de-
fault settings.
To reset the IFT-WFM with the IFT-RC400, while the IFT-
RC400 screen is active, press and hold the “P” button on
the back of RC400 remote control with a pin for 10 sec-
onds to reset the IFT-WFM. The IFT-ECM will beep and
reset the IFT-WFM.