Model SL-4100
Features
Light comes on when motion is detected.
Automatically controls existing post light.
DualBrite
®
Timer.
Photocell keeps the light off during daylight
hours.
This package includes:
© 2007 HeathCo LLC 595-5657-04
TEST
Requirements
The light control requires 120 volts AC.
If you want to use Manual Override, the
control must be wired through a switch.
Some codes require installation by a
qualified electrician.
Motion Sensing Post
Light Adapter
3 Wire Connectors
3 Screws
Post Light
Adapter
ON-TIME
MINUTES
ACCENT
Put ON-TIME switch on the sensor bottom
to TEST and the DualBrite
®
(ACCENT)
switch OFF.
MANUAL MODE
... back on.
1 Second
OFF then...
OPERATION
AUTO
Set ON-TIME switch to
1, 5, or 20 minutes.
Manual mode only works at
night because daylight re-
turns the sensor to AUTO.
Flip the light switch off for
one second then back on to
toggle between AUTO and
MANUAL MODE.
Manual mode works only
with the ON-TIME switch in
the 1, 5, or 20 position.
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1
1
/
2
minutes for the circuitry to calibrate.
Mode: On-Time Works: Day Night
Test 5 Seconds x x
Auto 1, 5, or 20 Min x
Manual To Dawn* x
Accent 3, 6 Hr, to Dawn x
DUSK TO DAWN
6 HOUR
3 HOUR
OFF
20
5
1
TEST
20
5
1
TEST
Before installation, record the model number
from back of fixture below. Attach receipt in
case of possible warranty issues.
Meets the ENERGY STAR
®
guidelines when DualBrite
®
function is off and ON-TIME
is 1 or 5 minutes.

Questions and Answers:

Heath Zenith Motion Sensing Post Light Adapter SL-4100 Specifications

General IconGeneral
BrandHeath Zenith
ModelMotion Sensing Post Light Adapter SL-4100
CategoryAdapter
LanguageEnglish

Summary

Operation Modes

Test Mode Setup

Configure the ON-TIME switch to TEST for sensor calibration and initial setup.

Auto Mode Setup

Set the ON-TIME switch to 1, 5, or 20 minutes for automatic operation.

Manual Mode Operation

Explains how to toggle and use manual override for the light control.

Installation Guide

Testing and Specifications

Testing Precautions

Advice on avoiding environmental factors that can cause false motion detection.

Product Specifications

Details on range, sensing angle, power, and operating modes.

Securing Fixture

Troubleshooting Common Issues

Light Not Coming On

Common causes and solutions for when the light fails to activate.

Light Stays On Continuously

Troubleshooting steps for lights that remain on without detection.

Light Flashes or False Triggers

Addresses issues of lights flashing or triggering for no apparent reason.

Technical Service Information

Limited Warranty Details