Page
116
Tune
up
the
Transmitter
using
steps
A
through
I
of
the
CW
tune-up
chart,
and
then
continue
as
follows:
SWITCH
OR
CONTROL
SWITCH
OR
CONTROL
POSITION
ALC
ADJUST
C,
LEVEL
D.
ANTI-VOX
The
VOX
DELAY
and
VOX
GAIN
controls
should
be
adjusted
to
suit
your
operating
convenience,
(_
)
Speak
into
the
microphone
normally,
using
VOX
operation,
Adjust
the
VOX
GAIN
con-
trol
for the
microphone
sensitivity
desired
to
turn
onthe
Transmitter,
The
VOX
DELAY
control
should
be
set
for
the
hold-in
time
desired
after
the
operator
stops
talking,
Gag
He4tuxir
COMMENTS
With
the
Meter
switch
in
the
ALC
position
during
transmitter
standby
periods,
it
is
norm-
al
for
the
meter
to
deflect
full
scale,
Adjust
for
zero
meter
indication
with
no
modu-
lation
and
with
the
push-to-talk
button
de-
pressed,
It
is
normal
for
the
meter
to
indicate
full
scale
when
the
Transmitter
is
in
STBY,
Adjust
for
midscale
(top
of
ALC
area)
meter
reading
on
peaks
while
the
Transmitter
is
being
modulated,
With
the
Receiver
set
to
a
strong
station
and
with
proper
listening
level,
advance
the
ANTI-
VOX
control
clockwise
until
the
Receiver
audio
will
no
longer
trip
the
VOX
circuit
of
the
Transmitter,