fa
NEUTRALIZING:
This
capacitor
is
adjusted
to
balance
out the
grid-to-plate
capacity
of
the
output
tubes,
RELATIVE
POWER:
Adjust
this
control
for
a
meter
reading
of
1/2
full
scale
when
the
transmitter
is
fully
loaded
on
80
meters,
BIAS
ADJUST:
With
driver
tube
(V9)
removed
and
key
down,
adjust
this
control
for
50
ma
of
plate
current,
FREQ.CONTROL:
This
switch
permits
the
se-
lection
of
either
the
internal
LMO
or
the
ex-
ternal
LMO
in
the
SB-301
Receiver,
In
the
UNLOCKED
position,
the
LMO
in
the
Trans-
mitter
and
the
LMO
in
the
Receiver
operate
independent
of
each
other,
In
the
LOCKED
(RCVR)
position,
the
LMO
in
the
Receiver
con-
trols
both
units,
ZERO
SET
KNOB
FINAL
LOAD:
This
control
is
adjusted
for
maximum
meter
indication
(REL
PWR),
Ittunes
the
Transmitter
for
maximum
output
by
matching
the
output
impedance
to
the
antenna,
FINAL:
This
control
is
adjusted
for
maximum
meter
indication
(REL
PWR).
It
tunes
the
Trans-
mitter
for
maximum
output
by
resonating
the
final
tank,
DRIVER:
This
control
is
adjusted
for
maximum
meter
indication
(REL
PWR).
It
tunes
the
driver
stage
for
maximum
output,
FUNCTION:
This
switch
is
set
for
the
desired
Transmitter
function,
such
as
OFF,
STBY,
TRCV,
TRAN,
and
SPOT.
LMO
DIAL
KNOB:
This
knot
the
Transmitter
for
the
desir
quency
of
the
selected
band
»
LMO
is
used,
BAND:
This
switch
determines
the
amateur
band
or
the
500
kHz
segment
of
the
band
on
which
the
Transmitter
is
to
operate,
FIGURE
1-2