Disinfection:
To disinfect the optical surfaces, use isopropyl alcohol with an alcohol level of 70% or
ethanol with an alcohol level of 80%.
To ensure decontamination, follow appropriate infection control guidelines regarding
surface disinfectant contact times.
At the end of contact time, check whether remnants of the disinfectant are visible on the
optical surface.
If there are remnants of the disinfectant, clean the optical surface by
using a clean, dry microfiber cloth to clean the objective lens with gentle circular
movements.
trying to add a few drops of pure alcohol, such as ethanol, or isopropanol.
How should I clean/disinfect the non-optical surfaces
of my SPECTRALIS?
Important Note:
Clean and disinfect the non-optical surfaces of the device with a moist,
not wet, cloth.
Do not use products containing acetone or hydrogen peroxide.
When the device is not in use, protect the objective with the objective
cover, and protect the device with the dust cover.
Cleaning:
For cleaning, any standard cleaning product appropriate for plastic and metal surfaces which
does not contain acetone or hydrogen peroxide may be used.
Disinfection:
In the USA, Heidelberg Engineering recommends Metrex CaviWipes
®
or other EPA registered
disinfectants with comparable active substances. Outside the USA, Heidelberg Engineering
recommends Descosept AF wipes, mikrozid® AF wipes, or comparable wipes with antibacterial,
antiviral, and antifungal effects. Follow the instructions of the disinfectant wipes manufacturer.
Do not use products containing acetone or hydrogen peroxide.
How should I clean/disinfect my SPECTRALIS touch panel?
Clean the touch panel with a moist, well wrung out microfiber cloth. Use a mild detergent for
cleaning the touch panel.
Please do not use detergents containing organic solvents, e.g. acetone, or hydrogen peroxide
when cleaning and disinfecting the touch panel as that may damage the touch panel’s coating.
Otherwise, the same disinfecting instructions for non-optical surfaces (above) can be followed.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HEIDELBERG Spectralis and is the answer not in the manual?

HEIDELBERG Spectralis Specifications

General IconGeneral
Scan SpeedUp to 85, 000 A-scans per second
Light SourceSuperluminescent diode (SLD)
OCT TechnologySpectral-Domain OCT
Wavelength870 nm
Fundus ImagingYes
Tracking SystemTruTrack Active Eye Tracking
Fundus Imaging ModalitiesIndocyanine Green Angiography
Field of ViewUp to 55°
OCT Scan PatternsRadial, Raster, Volume
Image ModesEn Face