EasyManua.ls Logo

Heitronics KT15 II User Manual

Heitronics KT15 II
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
INFRARED RADIATION
PYROMETER
KT15 II
Operating Instructions
95582944
13/08/06e
All rights reserved! The reproduction, transmission or use
of this document or its contents is not permitted without
express written authority. Offenders will be liable for
damages. All rights, including rights created by patent
grant or registration of a utility model or design, are
reserved. Heitronics GmbH reserves the right to make
modifications and improvements in their design without
prior notice.
(c) HEITRONICS Infrarot Messtechnik GmbH
HEITRONICS
Infrarot Messtechnik GmbH
Kreuzberger Ring 40
D-65205 Wiesbaden
Tel. ++49 (0)611 9 73 93-0
Fax ++49 (0)611 9 73 93-26
eMail info@HEITRONICS.com
internet: www.HEITRONICS.com

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Heitronics KT15 II and is the answer not in the manual?

Heitronics KT15 II Specifications

General IconGeneral
DisplayLCD with backlight
Spectral Range8 to 14 μm
Accuracy±1% of reading or 1°C (2°F), whichever is greater
Resolution0.1°C
Emissivity0.100 to 1.000 (adjustable)
Optics20:1
Power Supply9V battery
OutputAnalog: 0-20mA or 4-20mA, Digital: RS232

Summary

Safety Instructions

General Safety Precautions

General safety advice and warnings for operating the pyrometer.

Laser Operation Safety

Safety precautions specific to the operation of the integrated laser.

Declaration of Conformity

Preface

Data Sheet

General Pyrometer Information

Infrared Temperature Measurement Principles

Explains the principles behind infrared temperature measurement.

General Application Overview

Details the general applications of the pyrometer series.

Pyrometers for Measuring Metals

Specific use cases for measuring metal temperatures.

Pyrometers for Measuring Plastics

Specific use cases for measuring plastic temperatures.

Pyrometers for Measuring Glass

Specific use cases for measuring glass temperatures.

Pyrometers for Measuring Gases

Specific use cases for measuring gas temperatures.

Technical Specifications

Spectral Sensitivity

Defines the wavelength range of the device's spectral sensitivity.

Temperature Measuring Range

Specifies the operational temperature limits for measurement.

Temperature Resolution

Details the accuracy and resolution of temperature readings.

Permissible Ambient Temperature

Specifies the operational temperature limits for the device itself.

Analog Output Configuration

Details the configuration options for analog signal outputs.

Digital Interface (RS232C)

Specifications and parameters for RS232 serial communication.

Connector Type

Information regarding the type of electrical connector used.

Technical Information: Cooling Jacket WK15

Connector Assignment for RS232 Interface

Connector Assignment for RS485 Interface

Connector Assignment for 7-Pin Connector

Temperature Resolution: KT15.01 II / KT15.02 II

Temperature Resolution: KT15.21 II

Temperature Resolution: KT15.41 II / KT15.42 II

Temperature Resolution: KT15.81 II / KT15.82 II

Start-Up Procedures

Mechanical Mounting

Describes the various mechanical mounting options for the pyrometer.

Electrical Connection

Instructions for connecting the pyrometer to power and signal sources.

12-Pin Connector Assignment for Start-Up

7-Pin Connector Assignment for Start-Up

Pyrometer Operation Modes

Operation Without Serial Interface

Guidance for operating the device without serial communication.

Operation With Serial Interface

Instructions for operating the device via serial communication.

Optical Adjustment Methods

Describes methods for aiming the pyrometer at the target.

Aiming Procedures

Aiming with Laserpointer LP15

Using a laser pointer for accurate aiming.

Aiming with Adjusting Rods

Utilizing adjusting rods for precise aiming.

Operation and Application

Check Routines

Procedures for checking device errors and status.

Ambient Temperature Measurement

Configuration for continuous ambient temperature monitoring.

Remote Control via Digital Input

Controlling device functions using digital input signals.

Device Function Monitoring

Monitoring temperature, output signals, and power consumption.

Keyboard Operation

Using the device's physical keyboard for operation.

Menu Navigation

Detailed guide to navigating the device's menu structure.

Maintenance and Calibration

General Maintenance Information

General advice regarding maintenance of the pyrometer.

Cleaning the Lens

Procedure for cleaning the optical lens for accurate measurements.

Testing Display Accuracy

Methodology for checking and verifying measurement accuracy.