Trouble shooting chart
Illustration Information on
the hand
console
Flicke
r
times
No.
The date in the memory of the time counter is incorrect. The fault will not
stop the truck. When the electric lock is reconnected after being turned
off, the time counter will be set to zero if the alarm disappears.
EEPROM DATA KO11
The memory unit storing and setting parameters has fault and at that time
the truck stops working. Change the logical card if the fault still exists
when the electric lock reconnects after being turned off; if the fault
disappears, take care if the former data are washed out by the incorrect
data.
EEPROM PAR. KO12
The memory unit storing the type setting of the chopper has fault. Change
the logical card if the fault still exists when the electric lock
reconnects after being turned off; if the fault disappears, take care if
the incorrect value is put into the chopper’s set, so it needs resetting.
EEPROM CINF. KO13
Data related to the time counter in long term memory or parts related to
the fault display and parameter setting has fault. Change the logical card
if the fault still exists when the electric lock reconnects after being
turned off.
EEPROM OFF LINE14
The fault is similar to the fault 2. The difference is that even the data
is correct, the hardware configuration is not correspond with the one
accepted by the H2B.
CHOPPER NO CONF15