(FIG. 1) Circuit Board Inside of RV-45D Solar Charge Controller
Recommended Settings for Flooded Lead-Acid Batteries
(RV/Marine and “Golf-Cart” type Batteries)
1 2
3 4
HELIOTROPE PV
RV SERIES
REVISION F.1
TEMP COMP
ON OFF
HOUSE
EQ
FL
MODE:
“Mode” Jumper block
set on pins #1 & #2 for
“EQ” (Automatic Equalization)
“Dip Switches” set for 14.2 volts DC
#1 - ON
#2 - OFF
#3 - ON
#4 - ON
NOTE:
Turn Temp. Comp.
Off if you donʼt
install the sensor!
(FIG. 2) Circuit Board Inside of RV-45D Solar Charge Controller
Recommended Settings for Sealed Lead-Acid Batteries
(Absorbed Glass Mat and Gel Batteries)
1 2
3 4
HELIOTROPE PV
RV SERIES
REVISION F.1
TEMP COMP
ON OFF
HOUSE
EQ
FL
MODE:
“Mode” Jumper block
set on pins #2 & #3 for
“FL” (Automatic Float)
“Dip Switches” set for 13.4 volts DC
#1 - ON
#2 - OFF
#3 - OFF
#4 - ON
NOTE:
Turn Temp. Comp.
Off if you donʼt in-
stall the sensor!