Henco CU-REGK-230V - Page 19

Default Icon
23 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...

DEU
ENG
FRA
NDL
ITA
ESP
No. Description Setting
010
Heating system
Sets the existing heating system:
• Floor heating, standard (FBH St.)
• Floor heating, low energy (FBH NE)
• Radiator (RAD)
• Convector, passive (KON pas)
• Convector, active (KON akt)
0 = FBH St.
1 = FBH NE
2 = RAD
3 = KON pas
4 = KON akt
Standard: 0
020
Blocking of cooling
Deactivates the cooling function.
0 = activated
1 = deactivated
Standard: 0
030
Operating lock
Protects the deactivation of the operating
lock with a PIN.
0 = deactivated
1 = activated
Standard: 0
031
PIN operating lock
Sets the PIN for parameter 30.
0 ... 9999
Standard: 0000
040
External sensor
(CU-REGC-V  CUREGCV)
Registration of an external room sensor or
floor sensor. The registration of a room sensor
deactivates the internal sensor. If a floor sen-
sor is used, the minimum floor temperature
can be set via the Settings menu in the func-
tion “External floor sensor”.
0 = no external
sensor
1 = room sensor
2 = floor sensor
Standard: 0
041
Correction of actual temperature of exter-
nal sensor
(CU-REGCV  CUREGCV)
Corrects a deviating measurement of the ac-
tual temperature.
-2 ... +2°C
Standard: 0 °C
050
Duration of the display illumination
Sets the duration of further illumination of the
display after use.
0 ... 30sec.
in 5 second incre-
ments
Standard: 15sec.
Service menu