Follow precautions for safe operation and storage, avoid liquids, flames, and direct sunlight.
Electrical equipment is hazardous if misused or damaged; repairs by trained personnel only.
Second-generation economical mattress overlay for pressure ulcer prevention and treatment.
For patients classed as medium to high risk of developing pressure ulcers.
Not for patients with severe spinal injuries/fractures or those requiring deep cell mattresses.
Dynamic system with pump and alternating air mattress with three airway chambers.
Pump inflates all chambers to 120mmHg/150 Kg for seating or patient transfer.
Chambers A & B inflate, then A deflates, followed by B deflating in a cycle.
Adjust pump pressure for profiled beds; avoid profiling beyond 45° to prevent pressure points.
Step-by-step guide to setting up the mattress and pump system.
Ensure no sharp objects or fire hazards; remove patient if pump fails.
Explains power, pressure dial, static mode, and pressure monitor functions.
Details on air leakage/low pressure alarms and power off alarms.
Details power, pressure range, fuse, frequency, power, noise, and alternating time.
Details model, layers, CPR, and max loading weight.
Standard and severe infection control cleaning procedures for the mattress cover.
Maintenance and repair work must be done by appointed Herida Healthcare engineers.
Annual servicing by trained personnel is required to ensure safe and trouble-free usage.
Store in a well-ventilated, dry place away from direct sunlight and extreme temperatures.
Includes decontamination, electrical safety, filter changes, fuse inspection, and pressure testing.
Handle with care during loading, unloading, and transit; protect from elements and sharp objects.
Recommended during service intervals or between patients using a Herida Testing System.
Notes on fuses, emergency deflation, avoiding sharp objects, and proper disposal.
Lists included items: Mattress, Pump, Air tube, Mattress cover.
Inspect cover, zips, connectors, fasteners, and stitching for wear or damage.
Check casing, mains lead for damage, and test the power fail alarm system.
Follow guidance in the user manual at all times.
Provides a higher degree of protection against electric shock.
Indicates double insulation for electrical safety.
Symbol for correct disposal of electrical equipment (Waste Electrical and Electronic Equipment).
Do not use broken or damaged plugs or cables as they may cause electric shocks.
Ensure hands are dry before handling any electrical items to prevent shocks.
No exposure to water/splashing, as it may cause electric shocks or fire.
Only authorised/qualified personnel should dis-assemble, repair, or rebuild the product.
Addresses issues like improper plug connection, power cut, or broken fuse.
Covers disconnected tubes, CPR plug issues, and air leakage resolution.
Guides on adjusting pump pressure for mattress hardness/softness.
Addresses loose air hoses, CPR connection, and insufficient air pressure for inflation.
Recommends proper placement of the pump on a flat surface or bedframe.
Provides address, phone number, and email for Herida Healthcare Ltd.
Information on environmentally friendly and infection control disposal of products.