4.3 Intended use
Safety valves protect tanks and pipework systems against impermissible excessive pressure. Safety
valves represent the last line of safety for a tank or pipework system. They should be capable of
preventing impermissible excessive pressure when all other upstream regulating, control and monitoring
devices have failed. In order to ensure this operability, safety valves require special attention during their
assembly and maintenance.
A safety valve is a piece of equipment with a safety function for protecting pressure equipment when the
permissible limits are exceeded and is thus subject to Directive 2014/68/EU (Pressure equipment
directive) of the European Parliament and of the Council, article 2, section 4.
4.4 Operating data
Type
d
0
[mm]
Pressure
range
[bar]
Max. back
pressure
[%]
Temperature
[°C]
Medium
06001/06011
6,0
5.0 to 55
3%
-196 °C to +65 °C
See
section
"4.5
Media"
06002/06006/
06012/06016
1.0 to 55
-196 °C to +150 °C
06381
06386/06387
06416/06417
10,5
0.2 to 25
-196 °C to +185 °C
06386/06387
06416/06417
14,0
0.2 to 40
06388/06418
06383/06413
06430/06435
7,0
3.3 to 50
-60 °C to +150 °C
10,5
2.9 to 50
15,0
06388/06418
23,0
2.0 to 50
06389/06419
7,0
20 to 25
10,5
1.8 to 5.99
-196 °C to +60 °C
6.0 to 40
-60 °C to +150 °C
06420/06421
06425/06426
06440/06441
06445/06446
7,0
0.4 to 50
-196 °C to +185 °C
10,5
0.4 to 2.99
14,0
3.0 to 50
-196 °C to 150 °C
18,0
0.4 to 40
23,0
0.4 to 10
06472/06477
6,0
0.5 to 6.0
06474/06478
4.5 to 45
06800/06801
06805/06806
12,5
3.0 to 25.0
15%
-270 °C to +225 °C
15,0
20,0
23,0