herrmann HL 60 GLV.2-S Specifications

General IconGeneral
Burner typeGas burner
Power Output60 kW
Fuel TypeNatural gas / LPG
Voltage230 V
Frequency50 Hz

Summary

Technical Data

Functional description

Mixing device

Explains the mixing device function for efficient, clean combustion and minimal soot.

Combustion air blower

Describes the hybrid blower for reliable operation and reduced noise.

Fuel pump and nozzle closing system

Details fuel pump operation and LE system for controlled injection.

Flame monitoring

Discusses flame monitoring systems, including optical detectors and ignition units.

Ignition device

Explains the ignition device and its interaction with flame monitoring.

Oil firing unit

Covers control and monitoring by electromechanical and electronic units.

Initial operation

Assembly of the burner

Provides step-by-step instructions for physically assembling the burner.

Burner adjustment

Covers adjusting combustion airflow and settings for optimal performance.

Maintenance of the burner

Exchange of the nozzle and the diaphragm valve

Provides instructions for replacing burner nozzle and diaphragm valve.

Basic adjustment table

Expanded view with spare parts list

Malfunction diagnosis

Dimensions of the burner