1500 Series or 1600 Series Electric Strike
1500 Series and 1600 Series Electric Strikes
Installation Instructions
1
Product Components
Specications
1
2
3
ASSA ABLOY, the global leader
in door opening solutions
3
1
2
Pigtails (12 VDC and 24 VDC)
Trim Enhancer
MINIMUM WIRE GAUGE REQUIREMENTS
VOLTAGE
12VDC 24VDC
Solenoids are rated at +/- 10% indicated value.
* Applies to AC Only: 10% max duty cycle
(2 min. max on time)
200 feet or less
200 - 300 feet
300 - 400 feet
18 gauge
16 gauge
14 gauge
20 gauge
18 gauge
16 gauge
ELECTRICAL RATINGS FOR
1500E/1600E (EcoStrike™)
IN RUSH CURRENT
12 VDC
0.475A
24 VDC
0.460A
0.220A
0.215A
CONTINUOUS DUTY
10 VDC 30 VDC
VOLTAGE
NOTE: Installation wiring for the product and wiring methods shall be in accordance with the National Electrical
Code, ANSI/NFPA 70.
NOTE: The above table applies to Models 1500, 1500E, 1600, and 1600E.
Input voltage: 10–30 VDC, Autosensing
Ratings
Static Strength: 1,500 lbs
Dynamic Impact: 70 ft-lbs
Endurance: 250,000 cycles
Minimum Activation Duration: 1 second
0.010A
0.009A
0.005A
0.004A
ELECTRICAL RATINGS FOR
1500/1600 (Solenoid)
INTERMITTENT DUTY*
24 VDC
0.24A
12–16 VAC
0.12A
CONTINUOUS DUTY
12 VDC 24 VAC
VOLTAGE
0.24–0.32A
0.12A
- -
- -
UL294 Performance Levels
Destructive Attack: Level 1 (No attack test)
Line Security: Level I (No Line Security)
Endurance: Level IV (100,000 cycles)
Standby Power: Level I (No secondary power source)
4
4
5/64” Hex Wrench
5
#6-32 x 3/16” Phillips Head
Screws to Mount Trim Enhancer
5
Models 1500E and 1600E: For Indoor Use Only
Models 1500 and 1600: For Outdoor Use
3086006.001 Rev 3
Question and Answer IconNeed help?

Do you have a question about the HES 1500 Series and is the answer not in the manual?

Summary

Product Components Overview

Electrical and Performance Specifications

Electrical Ratings for 1500;1600 Series

Details voltage and duty cycle ratings for the standard 1500/1600 series solenoids.

Electrical Ratings for 1500 E;1600 E EcoStrike

Provides input voltage, in-rush current, and continuous duty ratings for the EcoStrike models.

General Ratings and UL294 Performance

Lists static strength, dynamic impact, endurance, and UL294 performance levels.

Converting the Operation Mode

Connecting the Power

Preparing the Frame

Metal Jamb Dimensions for Faceplates

Specifies cutout dimensions for metal jamb faceplates with or without lip extensions.

Selecting the Appropriate Faceplate Option

Faceplate Options and Compatibility Guide

Details faceplate options, their dimensions, and compatible lockset types.

Adjusting the Shim

Summary

Product Components Overview

Electrical and Performance Specifications

Electrical Ratings for 1500;1600 Series

Details voltage and duty cycle ratings for the standard 1500/1600 series solenoids.

Electrical Ratings for 1500 E;1600 E EcoStrike

Provides input voltage, in-rush current, and continuous duty ratings for the EcoStrike models.

General Ratings and UL294 Performance

Lists static strength, dynamic impact, endurance, and UL294 performance levels.

Converting the Operation Mode

Connecting the Power

Preparing the Frame

Metal Jamb Dimensions for Faceplates

Specifies cutout dimensions for metal jamb faceplates with or without lip extensions.

Selecting the Appropriate Faceplate Option

Faceplate Options and Compatibility Guide

Details faceplate options, their dimensions, and compatible lockset types.

Adjusting the Shim

HES 1500 Series Specifications

General IconGeneral
Voltage12/24 VDC
Static Strength1500 lbs
Endurance1, 000, 000 cycles
Security GradeGrade 1
Holding Force1500 lbs
DutyContinuous Duty