EasyManuals Logo

HESCH HE 5411 User Manual

HESCH HE 5411
39 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
8
HE 5411 Operating Instructions
#340411 | version 1.7
2.4 Device Identification
Note!
The HE 5411 differential pressure transducer is available in three
different designs. The corresponding device identification can be seen on
the nameplate. Devices with a measuring range of ± 1.25 mbar
(regardless of the device version) do not have any ATEX certification!
HE 5411 Lite
HE 5411 Basic
HE 5411 Premium
The devices with 19…36 V DC are marked with:
The devices with 100…240 V AC are marked with:
The devices with a measuring range of ±1.25 mbar are marked with:
II3D
Device category:
Use in Zone 22 for dust during normal operation
Ex
Denotes electrical equipment.
Standards of the EN 60079-0ff. series have been applied.
tc
Type of ignition protection:
Protection by housing
IIIC
Explosion group:
conductive dusts
T135°C
Temperature class:
maximum permissible surface temperature
Dc
Device protection level:
Use in Zone 22 for dust
IP65
Protection type:
dust-tight and protected against water jets