Specifications/Performance: 2.0
2
Specifications
H12HP1A
(1 Ton)
H12E1
(1 Ton)
H18HP2A
(1.5 Ton)
H18E2
(1.5 Ton)
Cooling Capacity
12000 BTU/hr 12000 BTU/hr 18000 BTU/hr 18000 BTU/hr
SEER
17 22 17 23.3
Refrigerant Type
R410A R410A R410A R410A
Heating Capacity
13000 BTU/hr 13000 BTU/hr 19000 BTU/hr 19000 BTU/hr
COP For Heating
- 2.93 3.46 3.40
Voltage
115 115 230 230
Frequency
60 60 60 60
Phase
1 1 1 1
Rated Current Cooling
10.8 Amps 8.3 Amps 7.6 Amps 6.3 Amps
Rated Current Heating
10.8 Amps 9.7 Amps 9 Amps 7.2 Amps
Air Circulation Indoor Unit (High CFM)
364 365 589 648
Indoor Unit Decibels
40 39 45 45
Outdoor Unit Decibels
54 53 54 55
User Care & Maintenance: 3.0
Disconnect power supply before cleaning or maintenance.
Cleaning Your Indoor Unit:
Use only soft, dry cloths to wipe the unit clean. If unit is extremely dirty, use a cloth soaked in warm water.
Do not use chemicals or solvents to clean the unit.
Do not use water hotter than 104° F as it may cause discoloration or deforming of the panel.
Cleaning The Air Filter:
A dirty or clogged air conditioner can decrease the cooling efficiency of your unit. It is recommended to clean
your air filters every 2 weeks or 200 hours of use.
Disconnect unit from power source(turn off breaker) prior to opening from cover to access pads. Lift up front
panel from lower corners to swing cover up. Fig. 3
Access Removable
Filters
Lift Cover At Corners
Fig. 3
Gently remove air filters from indoor unit.
Clean filters with warm soapy water.
Use a mild detergent.
Rinse with fresh water, dry completely.
Replace filters and close cover.