  • T
    Tina WilliamsAug 15, 2025
    How to troubleshoot Hettich LegaMove lifting columns that are not working?
    • K
      Kimberly CastilloAug 15, 2025
      If your Hettich LegaMove lifting columns aren't working, check these potential causes and solutions: * Ensure the power cord is connected to the control unit. * Verify the lifting column cables are connected to the control unit. * If the power cord is faulty, replace it. * Check for bad connector contact on the lifting column cable, power cord, and handset cable. * If the handset is faulty, replace it. * For a remote pushbutton, ensure it has a working battery or reprogram it. If these steps don't resolve the issue, the control unit or lifting column might be faulty, and you should contact customer service.
  • C
    cookscottAug 17, 2025
    What to do if Hettich LegaMove control unit or handset does not work?
    • M
      Melissa BradyAug 17, 2025
      If the control unit or handset for your Hettich lifting columns isn't working, try the following: * Make sure the power cord is securely connected to the control unit. * Ensure the handset is properly connected. * If the power cord is faulty, replace it. * For a remote pushbutton, ensure it has a working battery or reprogram it. * Check for bad connector contact on the lifting column cable, power cord, and handset cable. If the problem persists, the handset or control unit may be faulty and require replacement or further assistance from customer service.
  • A
    Aaron ParksAug 21, 2025
    Why Hettich lifting columns only move in one direction?
    • M
      Mark GonzalezAug 21, 2025
      If your Hettich lifting columns are only moving in one direction, it might be due to a power failure during movement or disconnection of the power cord. In this case, perform a manual reset. If the issue continues, the handset, LegaMove lifting column, or control unit may be faulty, and you should contact customer service or replace the handset.
  • J
    Jimmy BakerAug 25, 2025
    What to do if 'HOT' is shown on the display of Hettich lifting columns?
    • A
      ahollandAug 25, 2025
      If the display shows 'HOT', it indicates that the overheat protection in the control unit has been activated. Wait for the control unit to cool down until the message disappears. Once cooled, the control unit will be operative again.
  • V
    Victoria DavisAug 28, 2025
    What does error 71 mean on Hettich lifting columns?
    • D
      Dr. Joshua TrujilloAug 28, 2025
      To address error 71, which indicates an internal error, perform a manual reset by disconnecting the power cord, waiting a few seconds, and then reconnecting it. If the error persists, disconnect the power cord again and contact customer service.
  • S
    Sean HallAug 31, 2025
    What does error 55 mean on Hettich LegaMove Lifting columns?
    • M
      Mitchell WashingtonAug 31, 2025
      To resolve error 55, which indicates a synchronization problem with motor group 1, first remove the load from the furniture. Then, perform a manual reset. If the error reappears after the reset, contact customer service for further assistance.
  • M
    Michael TrujilloSep 3, 2025
    What does 'E' and an error number on the display of Hettich LegaMove Lifting columns mean?
    • M
      martinezjessicaSep 4, 2025
      If you see 'E' followed by an error number on the display, it indicates an internal error within the control unit. Proceed by consulting the error list for specific instructions.
  • T
    Thomas JonesSep 7, 2025
    What does error 67 mean on Hettich LegaMove Lifting columns?
    • D
      Donald ConleySep 7, 2025
      To address error 67, which indicates that the voltage is too high, disconnect the power cord and contact customer service.
  • C
    carrie34Sep 10, 2025
    What to do if the display shows four dashes on Hettich LegaMove Lifting columns?
    • S
      sarah90Sep 10, 2025
      If the display shows four dashes, it means the display handset was connected while the control unit was connected to mains power. Disconnect the power cable, leave the control unit without power for about 10 seconds, and then reconnect the power cable.