Bautrockner
Building Dryer / Déshumidificateurs
BT 450
Art.-Nr. / Item No. / Nº d’art.:1110628
Stand: 08/2011

Questions and Answers

  • K
    kcunninghamAug 16, 2025
    What to do if my Heylo Dryer compressor does not start?
    • D
      Don LopezAug 16, 2025
      If the compressor of your Heylo Dryer isn't starting, there could be several reasons: * The unit might need a 5-minute rest before restarting. Turn it off, wait 5 minutes, and then restart. * The overload protection may be preventing it. Try lowering the room temperature to below 38 °C. * There might be a faulty or broken wire. Replace or repair any broken or loose wires. * A defective relay could be the issue. Check the relay using a voltmeter/ammeter. * The unit might be in the middle of defrosting. Wait approximately 15 minutes. If none of these steps work, contact your dealer or HEYLO service center.
  • M
    Mary WardAug 19, 2025
    What to do if my Heylo Dryer unit does not start?
    • W
      William DunnAug 19, 2025
      If your Heylo Dryer unit isn't starting, it could be due to no voltage at the system or the switch not being turned on. Connect the unit to a live power socket and ensure the switch is turned on.
  • A
    Austin BushAug 22, 2025
    Why is my Heylo BT 450 unit collecting only minor water quantities?
    • J
      Jason ChangAug 22, 2025
      If your Heylo Dryer is collecting only minor water quantities, it could be due to the room being too dry, the room temperature being too low, or limited airflow through the unit. To resolve this, determine the air humidity using a hygrometer, increase the room temperature, and increase airflow by cleaning the filter and coils.
  • R
    rfullerAug 26, 2025
    What to do if my Heylo Dryer blower wheel does not run?
    • J
      Jeremiah HamiltonAug 26, 2025
      If the blower wheel on your Heylo Dryer isn't running, it could be due to a blockage, a loose or broken wire, or a faulty blower motor. Remove any blockage, replace any broken wires, and if necessary, replace the blower motor.
  • C
    Calvin DanielAug 28, 2025
    What to do if my Heylo BT 450 unit does not drain?
    • D
      Dana ClineAug 28, 2025
      If your Heylo Dryer isn't draining, it could be due to several reasons: * A fault with the pump. Clean the pump and replace any defective parts as needed. * The pump itself may be defective. Replace the pump. * The condensate hose might be clogged. Replace the condensate hose.
  • S
    Sherry WigginsAug 31, 2025
    Why is my Heylo Dryer unit permanently defrosting?
    • H
      housethomasAug 31, 2025
      If your Heylo Dryer is permanently defrosting, the room temperature might be too low, or the regulator could be defective. Try increasing the room temperature or replacing the regulator.
  • J
    janet57Sep 3, 2025
    What to do if my Heylo BT 450 Dryer is not defrosting?
    • M
      Michael HernandezSep 3, 2025
      If your Heylo Dryer is not defrosting, it could be due to a defective defrosting unit or a defective regulator. Replace the defrosting unit in either case.
  • M
    Mr. Aaron FreySep 6, 2025
    Why is my Heylo BT 450 Dryer not drying the room, even though it functions?
    • R
      Rachel SanchezSep 7, 2025
      If your Heylo Dryer is running but the room isn't drying, it could be due to several reasons: * Not enough drying time. Allow more time for drying. * Insufficient air movement. Increase air movement using HEYLO turbo dryers. * Too much intake of outside air. Reduce air inflow into the areas to be dried.
  • D
    Daniel RiveraSep 9, 2025
    Why is there no moisture or ice on the cooling coils of my Heylo BT 450 Dryer?
    • D
      Derek WrightSep 9, 2025
      If there's no moisture or ice on the cooling coils of your Heylo Dryer, it could be due to low temperature or air humidity. Measure the ambient atmosphere using a HEYLO MMS plus. Alternatively, the system may be leaking, so search for a leak using a gas detector. A damaged refrigeration system or a non-running compressor could also be the cause. Check the compressor, and if it's not running, contact your dealer or HEYLO service center.
  • T
    Tricia StanleySep 12, 2025
    Why is there ice or moisture only on one part of the cooling coils of my Heylo BT 450 Dryer?
    • A
      Allison SullivanSep 12, 2025
      If ice or moisture is only forming on one part of the cooling coils in your Heylo Dryer, the system may be leaking or have low system filling. Search for a leak using a gas detector, and repair and refill the system if necessary.

Heylo BT 450 Specifications

General IconGeneral
Voltage220-240 V
Frequency50 Hz
RefrigerantR134a
TypeCondenser
Power consumption2200 W
Dimensions (L x W x H)600 x 600 x 850 mm