If HS is set as 38.2 and LS is set as 37.4, then the desire temperature
(incubating temperature adjustment) can only be changed from 38.2 to 37.4,
so the minimum temperature shall be limited to 37.2 even if the is kept on
pressing. The same goes for the High Set Limit.
- This is to prevent accidental out of range temperature setting.
- These are settings I have never adjusted or attempted to adjust as
the heating unit starts and stops within I
O
C of my set temperature
of 37.6
0
C.
Il . Notice for first time of
incubatin
1. Test your incubator to see if its functions properly.
2.Connect the egg turner plug to the control plug inside the egg compartment.
3. Fill one or both water channels depending on local humidity levels.
4. Set the eggs with the pointy side down.
5. Close the lid and switch on the incubator.
6. Press the reset button (left green button) to reset and start the day counter
from O
(this will also rest the egg turning countdown back to 1:59)
Keep an eye on the humidity reading and fill the water
channels when needed. (normally every 4 days)
8. At day 18 you should remove the tray with the turning
mechanism and place the eggs on top of he bottom grid.
9. At the same time it is important to fill water channels to
increase the humidity. (this is very important to ensure
7.