Method
Method
Method
Method one
one
one
one Configuration
Configuration
Configuration
Configuration through
through
through
through Serial
Serial
Serial
Serial port
port
port
port
1. First
ly,
please ensure that the module is in default mode . The method of r estor ing the factory
settings : power-on the module, wait 35 seconds. Then press one of the buttons on the test
board and hold on more than 6 seconds.
2. Power-on the module again , wait 35 second s until the light on the module blinking, and then
connect the DB9 serial port with the computer's serial port in a straight line. Or connect t he test
board directly with a USB to serial cable as the following picture:
3. Press the "Exit transparent transmission / Preset" button, open the configuration software,
select the serial number, click on the search button , If there appears message >: at (: Found
Device at COM8 (115200)! I n the respose area, it means the module is found.