Questions and Answers

  • C
    Christopher McclainAug 15, 2025
    What to do if Hidro-Water Medical Equipment has unpleasant taste and smell?
    • S
      Shane BonillaAug 15, 2025
      If your Hidro-Water Medical Equipment produces water with an unpleasant taste and smell, it is likely due to contamination. You should replace the filters, membrane, and postfilter, and also sanitize the system.
  • K
    Kathy WilliamsAug 18, 2025
    What to do if Hidro-Water NEREO has zero or low production?
    • R
      robertrobertsAug 18, 2025
      If your Hidro-Water Medical Equipment has zero or low production, several factors could be responsible: * Check if the water supply has been restored. * Ensure the brass ball valve at the entrance is fully open. * Confirm the storage tank ball valve is fully open. * Verify the mains pressure is above 2.5 bars; if not, install a pump. * Inspect the storage tank for punctures or damage; replace if necessary. * Check and pressurize the storage tank to at least 0.25 bars when empty. * Replace obstructed flow restrictors or cartridges. * Unblock any obstructions in the drain line. * Replace the membrane if saturated. * Check the power supply and transformer output; replace the transformer if there's no voltage. * If the pump isn't increasing pressure, replace it.
  • A
    alvarezpamelaAug 21, 2025
    Why Hidro-Water Medical Equipment osmosis system doesn’t stop throwing water away?
    • D
      deborah10Aug 22, 2025
      If the Hidro-Water Medical Equipment osmosis system continuously throws water away, it could be due to: * A deteriorated shut-off valve (replace it). * A deteriorated non-return valve (replace it). * Excessive inlet pressure (fit a pressure regulator if the mains pressure exceeds 4 bars). * Very little air in the storage tank (pressurize the tank to between 0.25 and 0.4 bars when empty).
  • K
    Kelly LoveAug 25, 2025
    What causes excessive production and elevated TDS in Hidro-Water NEREO?
    • H
      Haley BowmanAug 26, 2025
      Excessive production or elevated TDS in your Hidro-Water Medical Equipment can be caused by several issues: * The membrane might not be fitted; ensure it is properly installed. * Damaged membrane O-rings should be replaced. * A damaged membrane housing requires replacement. * A damaged membrane should be replaced. * Badly connected tubes: Wire the connection between the wastage and the permeate properly. * If the shut off valve is damaged, replace it.
  • U
    ustanleyAug 28, 2025
    Why Hidro-Water NEREO Medical Equipment osmosis system starts up sporadically without water consumption?
    • S
      stephenslauraAug 29, 2025
      The Hidro-Water Medical Equipment osmosis system starting sporadically without water consumption can be attributed to: * A deteriorated non-return valve, which should be replaced. * Excessive inlet pressure; if the mains water pressure exceeds 4 bars, install a pressure regulator. * A leak in the system or faucet; repair the leak or replace the faucet.
  • C
    Connie GarciaSep 1, 2025
    Why Hidro-Water NEREO Medical Equipment osmosis system stops and starts?
    • J
      jessewebsterSep 1, 2025
      If the Hidro-Water Medical Equipment osmosis system frequently stops and starts, the possible causes are: * Very low inlet pressure (lower than 1 bar): Bypass the minimum pressure switch. * A faulty minimum pressure switch: Replace it. * A deteriorated non-return valve: Replace the non-return valve.
  • P
    Peter RodriguezSep 4, 2025
    How to fix high pressure in the storage tank of Hidro-Water Medical Equipment?
    • I
      iwilsonSep 4, 2025
      To fix high pressure in the storage tank of your Hidro-Water Medical Equipment, check the pressure when the tank is empty. It should be between 0.25 and 0.4 bars. If necessary, depressurize the tank.
  • J
    Jessica HunterSep 7, 2025
    What causes a bitter or acidic taste in Hidro-Water Medical Equipment?
    • J
      James ChavezSep 8, 2025
      A bitter or acidic taste in water from your Hidro-Water Medical Equipment is likely due to water with a very low salinity level. Fitting a mineralizing postfilter should resolve this issue.
  • B
    Brett RamosSep 12, 2025
    What causes a plastic or synthetic taste in Hidro-Water Medical Equipment?
    • J
      James BrooksSep 12, 2025
      A plastic or synthetic taste in the water from your Hidro-Water Medical Equipment is likely due to a worn postfilter. Replacing the postfilter should resolve this.