EasyManuals Logo

HIKVISION DS-2CD6365G0E-IVS User Manual

HIKVISION DS-2CD6365G0E-IVS
144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #116 background imageLoading...
Page #116 background image
User Manual of Network Fisheye Camera
106
Threshold: Range [5-100s], the threshold for the time of the objects removed
from the region. If you set the value as 10, alarm is triggered after the object
disappears from the region for 10s.
9. Drag the slider to set the sensitivity value.
Sensitivity: Range [1-100]. It stands for the percentage of the body part of an
acceptable target that leaves the pre-defined region.
Sensitivity = 100 – S
1
/S
T
*100
S
1
stands for the target body part that leaves the pre-defined region. S
T
stands for
the complete target body.
Example: if you set the value as 60, a target is possible to be counted as a
removed object only when 40 percent body part of the target leaves the region.
Note: The Sensitivity of the detection is supported by certain models. Refer to
actual display for details.
10. Repeat the above steps to configure other regions. Up to 4 regions can be set. You
can click the Clear button to clear all pre-defined regions.
11. Click Arming Schedule to set the arming schedule.
12. Click Linkage Method to select the linkage methods.
13. Click Save to save the settings.

Table of Contents

Other manuals for HIKVISION DS-2CD6365G0E-IVS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-2CD6365G0E-IVS and is the answer not in the manual?

HIKVISION DS-2CD6365G0E-IVS Specifications

General IconGeneral
BrandHIKVISION
ModelDS-2CD6365G0E-IVS
CategorySecurity Camera
LanguageEnglish

Related product manuals