page 1 February 2014
Product Data Sheet
HIT-HY 200
with HIT-Z
Basic loading data (for a single anchor)
All data in this section applies to
■ Correct setting (See setting instruction)
■ No edge distance and spacing inuence
■ Steel failure
■ Base material thickness, as specied in the table
■ Embedment depth, as specied in the table
■ One anchor material, as specied in the tables
■ Non cracked concrete f
c,cyl
= 32 MPa
■ Temperate range I (min. base material temperature -40°C, max.
long term/short term base material temperature: +24°C/40°C)
■ Installation temperature range -10°C to +40°C
Embedment depth and base material thickness for the basic loading data
Recommended loads
Anchor size M8 M10 M12 M16 M20
Typical embedment depth h
ef
[mm] 80 90 110 145 180
Base material thickness h [mm] 140 150 170 245 280
Recommended loads
Anchor HIT-Z
Anchor size M8 M10 M12 M16 M20
Tensile N
rec
[kN] 11.4 18.1 25.9 45.7 69.5
Shear V
rec
[kN] 6.9 10.9 15.4 27.4 41.7
Note: For varied embedment depths please contact your local Hilti engineer for further details.
Hilti HIT-HY 200 with HIT-Z
Injection Mortar System Benefits
■ no cleaning required: zero
succeptability to borehole cleaning
conditions with dry and water
saturated concrete base material
■
maximum load performance in
cracked concrete and uncracked
concrete
■
suitable for cracked and non-cracked
concrete C 20/25 to C 50/60
■
suitable for use with diamond cored
holes in non-cracked or cracked
concrete with no load reductions
Hilti HIT-HY 200-R
500 ml foil pack
(also available as 330 ml
foil pack)
Static mixer
HIT-Z
HIT-Z-R rod
CE
conformity
European
Technical
Approval
Concrete
A4
316
Corrosion
resistance
Tensile
zone
PROFIS
anchor design
software
No cleaning
required for
approved
loads
Seismic
Diamond
drilled
holes