When the installation is finished, it needs to connect the red/black conductors equipped
with faston coming from the power supplier to the battery. Be careful about connection polarity
(Red=positive [+] of the battery; Black=negative [-] of the battery), so that no cause great
damages to the connected devices.
After connecting the central unit and the siren batteries, it’s possible to power on the
system by the sectioning switch connected on the power supply/battery charger main power
clamps. The “RETE” LED signals the effective presence of the main voltage.
13Vcc regular output tension for volumetric detectors, telephone dialer, etc.
ATTENTION! Maximun current supplied: 400mA
13Vcc output tension on system enabled for the telephone dialer enabling.
13Vcc output tension in alarm condition for supplementary indoor sirens and
telephone dialer activation.
13Vcc output tension to recharge the autopowered siren. In alarm condition this
tension falls.
13Vcc output tension PX, SK or KB command systems.
(9) = red LED
(10) = green LED
NC* line (immediated).
NC* line (immediated).
NC* line (delayed).
* If the alarm zones are not used, the clamps must be arched.
The PROTEC3 and the power supply don’t need the ground connection, but for safety
reasons and for the respect of the laws in vigor we suggest to make and test the ground
connections of the all devices that need it.
2.3 Connections
1 - 2 Output in series to the key switch of the front panel. Cut to connect PX, SK or KB
command systems.
3 - 4
4 - 5
6 - 7
7 - 8
9 - 10 to command the LED on
11 - 12 24h anti-sabotage protection zone
11 - 13 Zone 1
11 - 14 Zone 2
InstallationPROTEC3 - User’s manual
ATTENTION!
The 12V7Ah battery must always be connected. Ensure of its efficient charge state,
measuring the tension by a volt-meter, after disconnecting the main power supply from
the power supplier/battery charger by the sectioning switch. Also in case of changing of
the lead battery it’s necessary to disconnect the main power supply from the power
supplier/battery charger, to avoid that the entire system burden on it.
Don’t connect on 13Vcc services power supply output of the central unit (clamps [4] and
[5] "+12V") a load beyond 400mA.
2.3.1 Electronic key
* This connection will activate the 24h anti-sabotage protection alarm when a false key is
inserted in the SKI connector.
A
B
C
D
SKI
SK100
Remove
the arch
In series to
the 24h line
ATTENTION!
Optional
connection*
securitysecurity