Please Read the Manual Carefully Before Installation
The following must be noted
Electrical connection
The appliance is fitted with a plug and must only be
connected to a properly installed earthed socket.
Only a qualified electrician who takes the appropriate
regulations into account may install the socket or replace
the connecting cable. If the plug is no longer accessible
following installation, an all-pole isolating switch must be
present on the installation side with a contact gap of at
least 3 mm. Contact protection must be ensured by the
installation.
Fitted units
The installation cabinet must not have a back panel behind
the appliance. Minimum installation height: 850 mm.
Ventilation slots and intakes must not be covered.
Installing the oven - Fig. 2
Note: Do not trap or kink the mains lead.