Why is my Hisense Projector showing a DLP system failure?
- DDarrell CarsonAug 27, 2025
A DLP system failure in your Hisense Projector can stem from a few potential issues: * The FFC (Flexible Flat Cable) connecting the display board and the DMD (Digital Micromirror Device) board might be poorly connected or faulty. Try reinserting or replacing the FFC. * The DMD part might not be correctly installed, or the DMD itself or the DMD board could be failing. Try reassembling the DMD, or replacing the DMD or the DMD board. * The display board itself could be faulty, requiring replacement.