- 8 -
• When the surface of the panel comes into contact with the cushioning materials, be sure to
confirm that there is no foreign matter on top of the cushioning materials before the surface of
the panel comes into contact with the cushioning materials. Failure to observe this precaution
may result in, the surface of the panel being scratched by foreign matter.
• When handling the circuit board, be sure to remove static electricity from your body before
handling the circuit board.
• Be sure to handle the circuit board by holding the large parts as the heat sink or transformer.
Failure to observe this precaution may result in the occurrence of an abnormality in the soldere
areas.
• Do not stack the circuit boards. Failure to observe this precaution may result in problems
resulting from scratches on the parts, the deformation of parts, and short-circuits due to residual
electric charge.
• Routing of the wires and fixing them in position must be done in accordance with the original
routing and fixing configuration when servicing is completed. All the wires are routed far away
from the areas that become hot (such as the heat sink). These wires are fixed in position with
the wire clamps so that the wires do not move, thereby ensuring that they are not damaged and
their materials do not deteriorate over long periods of time. Therefore, route the cables and fix
the cables to the original position and states using the wire clamps.
• Perform a safety check when servicing is completed. Verify that the peripherals of the
serviced points have not undergone any deterioration during servicing. Also verify that the
screws, parts and cables removed for servicing purposes have all been returned to their proper