b, higher temperature of discharging tube.
C, much noise
4)Low working
efficiency of
compressor
General when a compressor works for many
years, some parts of compressor were wear, so
that compressor disc
harge less gas out, unit
does not work strongly.
Phenomenon of failure:
a, lower pressure of discharging, check the
pressure of system with pressure meter to see
if it is normal.
b, higher temperature of compressor surface.
C, cut off the discharging tube, to see if you can
block the gas coming out of the tube when
compressor is working.
Change a new compressor.
5
) There is something
that blocked the liquid
cycle system
Some t ime there is something blocked the
filter of liquid cycle system, so that unit is not
cold.
Phenomenon of failure:
a, lower pressure of discharging
b, lower temperature of discharging.
Change a new filter
2.NO COOL
(Popular failure reasons are below):
Reason analysis Solutions:
1) Leakage of gas
Phenomenon of failure:
a, leaking fast
b, leaking slowly
c, no voice of liquid flowing
d, cut off charging tube, no gas goes
out.
First find out the point of leaking on tube, and
then sealed it, vacuuming it, finally recharge
with gas.
Note
If you find oil on somewhere, it is possible that
leakage point is there.
2)There is some thing
that blocked the liquid
cycle system
A,Ice blocking
Sometime because unknown reason
system, the capillary will be blocked
by water after unit runs for period of
time.
Phenomenon of failure:
The unit works well in the inception,
after period of time the ice appears
in the capillary and becomes more
and more, till blocks the hole of
capillary completely. In the moment
liquid flow disappears. The pressure
First stop unit for several minutes, and then
open charging tube, discharge all of gas. Blow
the cycle system with gas of nitrogen, and then
recharge Gas, finally sealed the system.