EasyManuals Logo

Hisense RD-31WC4S series User Manual

Hisense RD-31WC4S series
23 pages
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #23 background imageLoading...
Page #23 background image
The phenomenon above will appear
again and again.
The way to check ice blocking:
Warm the capillary with a hot towel,
after a while the ice in the capillary
melt, you can hear a sound of gas
abruptly. The pressure of absorbing
becomes higher. It is Ice blocking.
B, there is offal block the capillary
Phenomenon of failure:
If the capillary is blocked by
something such as offal etc., the
sound of liquid flow disappears.
The ice on the evaporator defrosts
The pressure of absorbing becomes
negative.
Higher temperature of discharging
tube
The way to check offal blocking:
If you warm capillary with the way of
checking ice blocking, there is no
change. It must be offal blocking.
First stop unit for several minutes, and then
open charging tube, discharge all of gas. Blow
the cycle system with gas of nitrogen. Change
a new capillary and filter, and then recharge
Gas, finally sealed the system.
COMPRESSOR NEVER STOPS
Reason Solutions
1) The setting temperature is not reasonable. Readjust the temperature setting.
2) the sensor is bad. Replace the sensor.
3) Seal of door is damaged. Replace the gasket
4) Too much food in the refrigerator Please put the food properly.
5) Wind door is broken. Replace wind door.
6) Fan motor is broken. Replace fan motor
Note:
Before doing these operations above, disconnect the main power supply. Failure to do so could result in
electrical shock or personal injury.
In case of any detailed technical information please check with the technical specifications.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hisense RD-31WC4S series and is the answer not in the manual?

Hisense RD-31WC4S series Specifications

General IconGeneral
BrandHisense
ModelRD-31WC4S series
CategoryRefrigerator
LanguageEnglish

Related product manuals