Handbrake is active when direction selected.
No speed feedback from external heatsink fans
Pump motor is not drawing sufficient current
Isolation fault detected between logic and power
frame
No speed feedback from motor
Tow mode has been activated
Invalid steer sensor state
Pulsed enable signal not present, unable to
enable bridge
Unable to complete power on checks to allow the
bridge to enable
MOSFET / IGBT s/c tests at power up are being
held off
Battery Electrolyte Low Level detected
Battery Electrolyte Low Level detected and
cutbcak
Warning level throttle fault. Used for Renault
Twizy
Throttle appears to be stuck. This fault will clear
if throttle starts to work again.
Throttle appears to be stuck. This fault will latch
and can only be cleared by repairing the throttle
and recycling power.
Analogue Output Over Current
(warn)
Contactor driver over current
Analogue Output Off with Failsafe
(warn)
Contactor driver not working
Analogue Output Over
Temperature (warn)
Contactor driver over temperature
Analogue Output Under Current
(warn)
Contactor driver unable to achieve current target
in current mode
Analogue Output Short Circuit
(warn)
Contactor driver MOSFET short circuit detected
Analogue supply is >10% out of range
seat regen settings applied