Page #17 background imageLoading...
Page #17 background image
17
CP-A100 / ED-A100 / ED-A110 (A1DN)
Lamp does not light
What
is the state of
LAMP indicator D303
during operation?
Is the
LAMP installation
correct?
Light
install the Lamp
PWB assembly
MAIN
Is the
voltage at
the (4) of E806 on
the PWB assembly MAIN
fixed to "L" during
warming-up?
NG
YES
“L” = 0V
Change the
lamp. Does lamp
light?
Lamp
Light
YES
Not light
Power unit (ballast) Power unit (circuit)
No
What
is the state of
TEMP indicator
D302?
Thermistor
(E1/E2)
Is
the voltage
at the (1) of E806 on the
PWB assembly MAIN set to
"L" during warming-
up?
Not light
and blink
PWB assembly MAIN
YES
“L” = 0V
Power unit (ballast)
No
Are
the voltage
supplied to the pin
(2) of connectors** for
DC fans soon after
the button is
pressed?
Observe
the voltage
waveforms at pin (1) of
connectors for DC fans**
soon after the button
is pressed.
Blinks
DC fan
(failed in above check)
Correct waveform is drawn below.
f 40Hz
PWB assembly
MAIN
NO (0V)
PWB assembly
MAIN
Correct
YES
incorrect
*: Be sure to unplug the power cord
before measuring resistance.
Not light
**: DC fan connectors are E801, E802,
E803, E804, E805 and E808.
(5V or higher)
Lights
Measure
resistance
of E1 and E2 after
disconnecting them
from MAIN
board.
OK
PWB assembly
MAIN
0.5 to 2k
NG (open / short)

Other manuals for Hitachi ED-A110A1DN

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi ED-A110A1DN and is the answer not in the manual?

Hitachi ED-A110A1DN Specifications

General IconGeneral
BrandHitachi
ModelED-A110A1DN
CategoryProjector
LanguageEnglish

Related product manuals