Items Optional Function Individual setting Setting condition Contents
FE Not prepared - - Not used (Use as 00 conditions)
FF Not prepared - - Not used (Use as 00 conditions)
H1 Not prepared - - Not used (Use as 00 conditions)
H2 Indication of hot start
×
00
01
Indication
No indication
H3 Not prepared - - Not used (Use as 00 conditions)
H4 Not prepared - - Not used (Use as 00 conditions)
J1 Temperature indication (*8) ×
00
01
Not available
Available
J2 Not prepared - - Not Used
J3 Run indicator color
×
00
01
Green
Red
J4 Not prepared - - Not used (Use as 00 conditions)
J5 Not prepared
×
- Not used (Use as 00 conditions)
J6 Error sound
×
00
01
Once
Sequence
J7 Not prepared - - Not Used (Use as 00 conditions)
J8 Eco-operation (*9)
×
00
01
(*10)
Not available
Available
J9 Not prepared - - Not used (Use as 00 conditions)
JA Not prepared - - Not used (Use as 00 conditions)
Jb Not prepared - - Not used (Use as 00 conditions)
K1 Not prepared
×
- Not used
K2 Not prepared
×
- Not used
K3 Not prepared
×
- Not used
K4 Not prepared - - Not used
K5 Human sensor detection level (*11) -
00
01
02
Standard
High
Low
*1: The “02” setting may not be available according to the type of indoor unit.
*2: In case of RPI models, 00: standard, 01: high static pressure, 02: low static pressure
*3: E1 to E4: Setting for the total heat exchanger.
*4: In case that the set temperature is changed and kept within the set time at “F4”, the temperature is automatically changed to “F5”
and “F6”. (In case that the set temperature is out of range at “F5” and “F6”, it is applied within upper and lower limit for the set
temperature.)
*5: Applicable to fan, cooling and dry operation modes.
*6: Applicable to heating operation mode.
*7: Operation is stopped by pressing the “ ” (run/stop) switch for 3 seconds.
*8: The value of the sensor selected by C8 setting will be displayed on the remote control. When the remote sensor is connected on
THM4, the average value of this remote sensor and of indoor unit inlet sensor will be displayed.
*9: When the unit is restarted by the remote control switch, the temperature automatically changes to the setting temperature of “F5”
or “F6”.
*10: If function F2 is set up 01 (Sub) is displayed “--”.
*11: This function is for air panel with motion sensor. If the air panel don’t have available the motion sensor, setting condition is
displayed as “--”.
? NOTE
After at least 3 minutes from the power ON, change the optional setting.
When changing “CF” setting (change of louver swing range), restore the power supply or allow the louver to make one complete swing fully in the
auto swing mode to apply the optional setting.
The optional settings are different according to the indoor and outdoor unit models. Check to ensure that the unit has the optional setting or not.
Record the setting conditions for each optional setting in the “Setting” column of the table.