--- 14 ---
8-6. Insulation Tests
On completion of disassembly and repair, carefully measure the insulation resistance and conduct a dielectric
strength test.
Insulation resistance: 7 M or more with 500 V DC megohm tester
Dielectric strength test: AC 4,000 V/1 minute with no abnormalities .................... 220 V -
--
240 V products
AC 3,500 V/1 minute with no abnormalities .................... 110 V -
--
127 V products
8-7. No-load Current Value
After no-load running for 30 minutes, the no-load current value should be as follows.
Voltage (V)
Current (A) max.
110
2.6
220
1.2
240
1.2
230
1.2