(3) Installation
Securely fix the outdoor unit on the foundation to prevent collapse in a strong wind or an earthquake or noise due to loss of
level (leaning aside).
1) Secure the unit on the foundation with anchor bolts.
2) Anchor bolt size.
3) Verify drainage and drain pipe installation.
● Water will drain from the unit when it rains. Install the
unit at locations with good drainage and drain water to
the ditch. Also, avoid install the unit overhead as water
will drip from the unit. Plan drainage for the secondary
condensate tray if overhead installation is necessary.
Unit: mm
Model A B C D E
RAC-112SQB
700 420 255 106 307
RAC-125SQB
RAC-140SQB
RAC-160SQB
※ Maintain this distance at much as possible to install
there is adequate space for piping.
4) Example of fixing the stand with anchor bolts:
Make sure to cut off section A when using this type of
anchor bolts. Otherwise, it will be difficult to remove the
pipe cover.
5) Securely fix the outdoor unit on the foundation to prevent
collapse in a strong wind or an earthquake or noise due to
loss of level (leaning aside).
6) When using ordinary frames whose legs are narrower than
the legs of the outdoor unit, add a board under the legs of
the outdoor unit as shown in the figure before installation
to ensure all legs of the outdoor unit are adequately
supported on the frame.
A
C
D
B
E
u
Outdoor unit stand
Special washer
Anchor
bolt (M10)
Mortar
Concrete
21mm-
Anchor bolt
Concrete
Under 21mm
(After cutting off A)
Drain hole
Outdoor Unit Leg Width: 70mm
The frame’s legs
are narrower
than the outdoor
unit’s legs.
Ordinary Frame
Frame Leg Width: 60mm
(Example of ordinary frames)
Recommended board size: SPHC material (prepared onsite)
Unit: mm
Board thickness: 4.5mm
2-holes
The frame’s legs
are narrower than
the outdoor unit’s
legs.
Outdoor Unit Leg Width: 70mm
Board Width: 100mm
Board
Ordinary Frame