17
MAIN PARTS COMPONENT
THERMOSTAT
Thermostat Specifications
FAN MOTOR
MAIN ELECTRIC COMPONENTS FOR OUTDOOR UNIT
Fan Motor Specifications
CONNECTION
TEMPERATURE
°C (°F)
INDICATION
16
INDICATION
24
INDICATION
32
MODEL RAS-14EH1
THERMOSTAT MODEL IC
OPERATION MODE COOL HEAT
ON 16.7 (62.1) 18.7 (65.7)
OFF 16.0 (60.8) 19.3 (66.7)
ON 24.7 (76.5) 26.7 (80.1)
OFF 24.0 (75.2) 27.3 (81.1)
ON 32.7 (90.9) 34.7 (94.5)
OFF 32.0 (89.6) 35.3 (95.5)
M
RED
BLK
WHT
YEL
BLU
35V
5V
0V
0 ~ 5V
FG
MODEL
NAME RATING APPLICABLE MODELS
REVERSING VALVE COIL 135 (20 ˚C) RAC-14EH1
REACTOR L1 13 (mH), 0.224 RAC-14EH1
REACTOR L2 25.5 (mH), 0.37 RAC-14EH1
FILM CAPACITOR 45 (µF) RAC-14EH1
RAS-14EH1
POWER SOURCE DC 5V, 35V
DC 140
~ 350
V
OUTPUT 25W
40W
(Control circuit built in)
BLU : BLUE YEL : YELLOW BRN : BROWN WHT : WHITE
GRY : GRAY ORN : ORANGE GRN : GREEN RED : RED
BLK : BLACK PNK : PINK VIO :
VIOLET
RED
140~
350V
BLK
0V
WHT
15V
M
YEL
0~6V
BLU
0~15V
RAC-14EH1
07B065_RAS-14EH1_015-018_E 2007.2.6, 9:15 AM17